4.3.2. Dosage in automatic mode (« LOC.MEM », « MEM+MANU », or « EXT.MEM »
Options)
The automatic mode enables the generation of a dose quantity from one of the 7 values
already entered into the memory. The dose quantity can be initiated either from the keypad
or by using the binary data inputs.
Initiating the dosage from the keypad (« LOC.MEM », « MEM+MANU » Options)
ENTER
BATCH A
Zero quantities (from V1 to V7) will not be displayed.
Initiating the dosage from the binary data inputs (« EXT.MEM » Option)
2885 L
Choice of quantity from
memory by encoding the
binary data inputs 1, 2 and 3.
« ALARM » prompt during dosage operation: dosage problem (see § 5.1.)
During dosage of the selected quantity, it is possible to display the flow rate, to pause, to
reset or to stop the operation (see § 4.3.4. and § 4.3.5)