BATCH CONTROLLER 8025
4 CONFIGURATION
Programming is carried out using three menus and is the same for all versions of the
equipment (compact, panel and wall mount).
Main menu
Using this menu the user can control the dosing using the keypad (start, pause, reset,
stop); using a readout, he can monitor the flow rate and the initial preset quantity throughout
the dosage operation. The readings of the main counter and the daily counter are displayed
in this menu. The daily counter can be set to zero.
Calibration Menu
This menu enables the setting of dosage parameters (languages, measurement units,
equipment, K factor, dosage option, overfill correction, alarm and relay thresholds).
Simultaneous resetting of the two counters is carried out in this menu.
Test Menu
This menu enables the user to check the binary inputs (remote control) and to simulate the
operation of the relays.
It also caters for measuring the rotation frequency of the paddle wheel (Hall effect or coil)
4.1 Description of Dosage Options
Dosage options are selected in the «OPTION» sub-menu of the Calibration Menu. (see
§ 4.4.4.)
4.1.1. « LOC.MANU» Option»
When this option is selected, the prompt « BATCH M » is displayed in the main menu. It
enables the generation of a dose quantity which can be defined using the keypad. (see §
4.3.1.)
4.1.2. « LOC.MEM » Option
When this option is selected, the prompt « BATCH A » is displayed in the main menu. This
option enables the generation of a dose quantity which has already been entered into the
memory (7 in total) from the keypad (see § 4.3.2.).
4.1.3.» MEM.MANU » Option
When this option is selected, the prompts « BATCH M » and « BATCH A » are displayed in
the main menu. This option enables the generation of a dose quantity either manually or
automatically. (see § 4.2.1. and § 4.2.2.).
E-17-