4 CONFIGURATION

4.3 Main menu

In the main menu, following readouts are available:
BATCH M
BATCH A
0......9
24563 L
456 L.
The following sub-routines describe the various dosage options together with the prompts
displayed in the main menu. The characters in grey flash when displayed.
4.3.1.Dosage in manual mode» LOC.MEM » or « MEM+MANU » Options
This mode enables the generation of a dose quantity which has already been entered from
the keypad.
ENTER
BATCH M
The dose quantity must be greater than 0.2 times the K factor (in litres). The entry of a zero
quantity forces a return to the « BATCH M » option.
The « ALARM » prompt during a dosing operation signifies a dosing problem (see § 5.1).
During the generation of the quantity which has been entered it is possible to display the
flow rate, to pause, to reset or to stop the dosage operation. (see § 4.3.4. and § 4.3.5.).
8025-BATCH-**
Dosing in manual mode (see § 4.3.1.). It is only available if the
« LOC.MEM » or the « MEM+MANU » Options have been selected
in the Calibration menu (see § 4.4)
Dosing in automatic mode (see § 4.3.2.). It is only available if the
« LOC.MEM » or the « MEM+MANU » have been selected in the
Calibration menu (see § 4.4)
Main counter using the selected measurement unit (see
Calibration menu). Zero setting in the Calibration menu.
Daily counter using the same measurement unit as the main
counter. A decimal point after the unit differentiates it from the
main counter. Zero setting by simultaneously pressing the two
keys
for 3 seconds.
0......9
00000
L
Entering of dose
quantity
0......9
ENTER
00100 L
E-21-
BATCH CONTROLLER 8025
ENTER
OK
O/N
ENTER
OK
O/N
Countdown of
quantity to 0
00100