FC 4370
180001030
180001020
m3/h
Remote / local mode
The icon shows whether the blower is set to remote or local control.
Remote control: The blower is controlled via digital inputs on the PLC or
via the data bus, and cannot be operated from the operator panel.
Local control: The blower is controlled from the operator panel. The pa-
rameters that can be controlled from the control panel are selected by
user Tech or Admin in the Settings menu.
In case the operator has no rights to switch between remote and local,
the symbol does not appear.
Version
FC 4370: Specifies the blower model.
180001030 / 180001020: Indicates HMI / PLC software version.
Operating status
The screen shown here is the current operating status of the blower.
FC 4370
The example shows:
180001030
180001020
1. m
/h - This is the unit of measurement for air speed. The control is
3
set to control how much air speed the blower delivers.
2. Vertical scale from 0 to 6000 - Scale showing the air speed. The
green part of the scale shows how much air speed the blower is
capable of delivering in the current situation.
3. 2500 - Indicates the set point, in m
4. 2505 - Indicates the current air speed of the blower, in m
Green blower icon - the blower runs as desired.
Green blower icon flashes - the blower is starting up or is unable to
reach the set point.
Red blower icon - the blower is stopped.
Red blower icon flashes - the blower is about to stop.
/h.
3
/h.
3
17