External start / stop contact (MultiAir FC/FCE)
Part no.
Type
100 503 357
External start / stop contact
The external start / stop switch is connected in terminal
block X30 between terminal 1 (+ 24VDC) and 3 (Digital
Input 0), and a loop is installed between terminals 1
and 5.
No setup is required on the operator panel.
The screen for the blower inputs and outputs looks like
this.
10
External motor control (MultiAir FC/FCE)
Part no.
100 503 338
100 503 345
100 503 341
100 503 342
100 503 339
100 503 343
100 503 340
The start / stop switch and the control boxes are all
specified 3x200V-600V 50/60Hz. If the motor controls
are used at voltages other than 400 - 440V, the power
consumption must be compensated.
The external motor control is connected in terminal
block X30.
For external motor 1: Terminal 2 (0 VDC) and terminal
+24 V DC
15 (Digital output 2)
For external motor 2: Terminal 2 (0 VDC) and terminal
0 V DC
16 (Digital output 3)
Each output in terminal block X30 may be loaded con-
tinuously with a maximum of 2A (24VDC), and a maxi-
mum of 4 Kongskilde motor controllers per output may
be connected.
Furthermore, a possible delay can be configured, see
section "Setting up the blower via the operator panel".
The connection below shows connection of external
motor 1.
No setup is required on the operator panel. The screen
for the blower inputs and outputs looks like this.
Type
External motor control 0,55kW (at 400V) 1,3-1,7A
External motor control 0,75kW (at 400V)1,7-2,3A
External motor control 1,1kW (at 400V) 2,3-3,1A
External motor control 1,5kW (at 400V) 3,1-4,2A
External motor control 2,2kW (at 400V) 4,2-5,7A
External motor control 3kW (at 400V) 5,7-7,6A
External motor control 4kW (at 400V) 7,6-10A