Télécharger Imprimer la page

Franklin Electric Cerus X-Drive Serie Manuel Du Propriétaire page 117

Publicité

Commandes ModBus et adresses de données
Nom affiché en
ModBus
anglais
8192
Run Command
8193
Frequency Command
8194
Fault Reset
8448
Error Code
8449
Drive Status
8450
Frequency Command Value Valeur de commande de fréquence
8451
Output Frequency
8452
Output Current
8453
DC-Bus Voltage
8454
Output Voltage
8455
Multi-Step Speed
8456
Reserved
8457
Counter Value
8458
Power Factor Angle
8459
Torque
8460
Motor Speed
8461
Reserved
8462
Reserved
8463
Output Power
8470
Multi-Function Display
8475
Maximum Operating Fre-
quency
8479
Decimal Portion of Output
Current
8704
Output Current
8705
Counter Value
8706
Output Frequency
8707
DC-Bus Voltage
8708
Output Voltage
8709
Power Angle
8710
Motor Power
8711
Motor Speed
8712
Torque
8713
Reserved
8714
PID Feedback Value
8715
AVI1 Input Value Percen-
tage
8716
ACI Input Value Percentage Pourcentage de la valeur d'entrée ACI
8717
AVI2 Input Value Percen-
tage
8718
IGBT Temperature
8719
Ambient Temperature
8720
Digital Input Status
8721
Digital Output Status
8722
Multi-Step Speed Being
Executed
8723
CPU Pin Status for Digital
Inputs
8724
CPU Pin Status for Digital
Outputs
8725
Reserved
8726
Reserved
8727
Reserved
Nom affiché en français
Exécuter la commande
Commande de fréquence
Réinitialisation du défaut
Code d'erreur
État du variateur
Fréquence de sortie
Courant de sortie
Tension du bus CC
Tension d'entrée
Vitesse multiétapes
Réservé
Valeur du compteur
Angle du facteur de puissance
Couple
Vitesse du moteur
Réservé
Réservé
Puissance de sortie
Affichage multifonctions
Fréquence de commande maximum
Portion décimale du courant de sortie
Courant de sortie
Valeur du compteur
Fréquence de sortie
Tension du bus CC
Tension de sortie
Angle de puissance
Puissance du moteur
Vitesse du moteur
Couple
Réservé
Valeur de rétroaction PID
Pourcentage de la valeur d'entrée AVI1
Pourcentage de la valeur d'entrée AVI2
Température IGBT
Température ambiante
État de l'entrée numérique
État de la sortie numérique
Vitesse multiétapes exécutée
État des broches du processeur pour
les entrées numériques
État des broches du processeur pour
les sorties numériques
Réservé
Réservé
Réservé
ModBus Nom affiché en anglais
8728
Reserved
8729
Counter Overload Time Percen-
tage
8730
GFF Percentage
8731
DC Bus Ripple
8732
PLC Register D1043 Data
8733
Reserved
8734
User Page Display
8735
Output Value of Output Fre-
quency Coefficient Calculation
8736
Number of Motor Revolutions
While Running
8737
Operating Position of the Motor Position de fonctionnement du moteur
8738
VFD Cooling Fan Speed
8739
Control Mode
8740
Carrier Frequency Status
8741
Reserved
8742
Drive Status
8743
Reserved
8744
Reserved
8745
Power
8746
AVI1-PT100
8747
ACI-PT100
8748
Reserved
8749
Reserved
8750
PID Reference Value
8751
PID Offset Value
8752
PID Output Frequency
8753
Hardware ID
8754
U-phase Current
8755
V-phase Current
8756
W-phase Current
8759
Aux Analog Input
8762
Torque %
9729
Digital Input Status
9730
Digital Input Status Continued
9793
Digital Output Status
9825
AVI1 Proportional Value
9826
ACI Proportional Value
9827
AVI2 Proportional Value
9835
Expansion Card AI10 Percentage Pourcentage fiche supplémentaire IA10
9836
Expansion Card AI11 Percentage Pourcentage fiche supplémentaire IA11
9856
AO1 %
9857
AO2 %
9889
AFM1 Output Proportional Value Valeur proportionnelle de sortie FFA1 (AFM1)
9890
AFM2 Output Proportional Value Valeur proportionnelle de sortie FFA2 (AFM2)
9899
Expansion Card AO10 Percen-
tage
9900
Expansion Card AO11 Percentage Pourcentage fiche supplémentaire AO11
COMMUNICATIONS
Communication Modbus
Nom affiché en français
Réservé
Pourcentage du temps de surcharge du compteur
Pourcentage GFF
Ondulation du bus CC
Données du registre API D1043
Réservé
Affichage de page d'utilisateur
Valeur de sortie du calcul du coefficient de fré-
quence de sortie
Nombre de tours du moteur pendant le fonctionne-
ment
Vitesse du ventilateur de refroidissement du VDF
Mode de contrôle
État de fréquence porteuse
Réservé
État du variateur
Réservé
Réservé
Puissance
AVI1-PT100
ACI-PT100
Réservé
Réservé
Valeur de référence PID
Valeur de décalage PID
Fréquence de sortie PID
ID du logiciel
Courant de phase U
Courant de phase V
Courant de phase W
Entrée analog. aux.
Couple %
État de l'entrée numérique
État de l'entrée numérique (suite)
État de la sortie numérique
Valeur proportionnelle AVI1
Valeur proportionnelle ACI
Valeur proportionnelle AVI2
AO1 %
AO2 %
Pourcentage fiche supplémentaire AO10
117

Publicité

loading

Ce manuel est également adapté pour:

Cerus x-drive cxd-005a-2vCerus x-drive cxd-007a-2vCerus x-drive cxd-010a-2vCerus x-drive cxd-015a-2vCerus x-drive cxd-021a-2vCerus x-drive cxd-031a-2v ... Afficher tout