Télécharger Imprimer la page

Bosch BAT 690 Notice Originale page 22

Chargeur pour batteries 12 volts et 24 volts

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 95
en
| 22 | BAT 690 | Configuration
6.2
Language
The "Language" menu is used to set the BAT 690
program language.
i
After switching the device on or after resetting it to
factory settings, the "Language settings" menu is
displayed automatically.
1. Select the "Language" menu item.
2. Press
.
 The "Language" menu is displayed.
3. Select the language with
4. Press
.
 The language is selected and the "Configura-
tion" menu is displayed.
6.3
Contrast
The "Contrast" menu is used to set the contrast of the
TFT display.
1. Select the "Contrast" menu item.
2. Press
.
 The "Contrast" menu is displayed.
3. Set the contrast with
4. Press
.
 The contrast is set and the "Configuration"
menu is displayed.
6.4
Self-test
The BAT 690 is checked in the "Self-test" menu. To do
this, a functional battery must be connected via the
charging cables.
1. Select the "Self-test" menu item.
2. Connect charging cables to the battery.
3. Press
.
 The "Self-test" menu is displayed.
4. Press
.
 Self-test is performed.
 The result of the self-test is displayed, e.g.
self-test successful
no errors
.
5. Press
.
 The "self-test" is complete and the "Configuration"
menu is displayed.
6.5
Software version
The "Software version" menu displays the current
software version of the BAT 690.
1. Select the "Software version" menu item.
2. Press
.
 The software version is displayed.
3. Press
.
 The "Configuration" menu is displayed.
|
1 689 989 234
2022-01-24
or
.
or
.
6.6
Factory setting
The customer-specific parameters are deleted and
replaced by the factory parameters in the "Factory
setting" menu.
1. Select the "Factory setting" menu item.
2. Press
.
3. Press
.
 The factory parameters are applied and the
"Configuration" menu is displayed.
6.7
Software update
Software updates for BAT 690 are available on
the Automotive Service Solutions Website at
www.downloads.bosch-automotive.com
can be downloaded to PC/laptop from the website.
To install the software update on the BAT 690, the
BAT 690 must be connected to the PC/laptop via a
USB connecting cable.
6.8
Instructions in case of faults
Fault
Action to be taken
BAT 690 not working
Disconnect mains plug and check the
after being switched
power supply and power supply cable.
on, red LED does not
light up.
Red LED flashes
Check the polarity at the battery:
after the battery has
red charging clip – positive terminal (+),
been disconnected.
black charging clip – negative terminal (–).
Fault message
Action to be taken
No battery connected
No battery connected or battery
voltage too low.
Warning!
Check if the correct battery is
Overvoltage
connected.
Error! Call customer
Inform customer service.
service
Warning!
Check the polarity at the battery:
Check clips
red charging clip – positive terminal (+),
black charging clip – negative terminal (–).
Fault no.
Action to be taken
10
Check the polarity at the battery:
red charging clip – positive terminal (+),
black charging clip – negative terminal (–).
20
No battery connected or battery voltage too low.
30
Battery overvoltage, check battery.
200, 210,
Check set charging parameters and battery.
220, 230
290
Switch off BAT 690 and wait 10 seconds, then
switch back on and check charging parameters.
310
Battery short circuit, check battery.
320
Battery defective, check battery.
360
Excessive temperature in the BAT 690, switch off
BAT 690 and allow it to cool down.
370
Insufficient temperature in the BAT 690, warm up
BAT 690.
In case of any other malfunctions or fault numbers,
inform customer service.
. The software update
Robert Bosch GmbH

Publicité

loading