Para-
Parameter name
meter
S6.18
HEAT PUMP - OUTDOOR
TEMP. FOR BIVALENT
OPERATION MODE
S6.19
HEAT PUMP - MIN.
OUTDOOR TEMP. FOR
MONOVALENT OPERATI-
ON MODE
PARAMETERS FoR FLooR DRyING
Group F1 contains the parameters for the setting of floor drying.
The procedure for F parameters setting is the same as the procedure for
service settings (see 41).
Table with descriptions of parameters:
Para-
Parameter name
meter
F1.1
FLOOR DRYING
F1.2
INTERVAL 1: DURATION
F1.3
INTERVAL 1: START TEMPERATURE
F1.4
INTERVAL 1: END TEMPERATURE
F1.5
INTERVAL 2: DURATION
F1.6
INTERVAL 2: START TEMPERATURE
F1.7
INTERVAL 2: END TEMPERATURE
F1.8
INTERVAL 3: DURATION
F1.9
INTERVAL 3: START TEMPERATURE
F1.10
INTERVAL 3: END TEMPERATURE
F1.11
INTERVAL 4: DURATION
F1.12
INTERVAL 4: START TEMPERATURE
F1.13
INTERVAL 4: END TEMPERATURE
Parameter description
Setting of outdoor temperature for bivalent operation
mode of heat pump and other heat source. Below setted
temperature the controller makes switchover between
heat sources immediately when heat pump cannot supply
requested temperature. Above setted temperature the
controller makes switchover between heat sources on
behalf of temperature deficit i.e. with delay. This principle
of switchover between heat sources provides maximum
efficiency and optimal use of heat pump, even when it
solely cannot cover complete heating demand.
Setting of minimum outdoor temperature for system with
heat pump and other heat source, above which solely
heat pump operation is allowed.
53
Setting range Default
setting
-30 ÷ 20 °C
-3
-30 ÷ 20 °C
7
Setting range
Default
setting
0- NO
1- CIRCUIT 1
0
2- CIRCUIT 2
3- CIRCUIT 1 & 2
1 ÷ 15 days
10
10 ÷ 60 °C
20
10 ÷ 60 °C
20
1 ÷ 15 days
5
10 ÷ 60 °C
20
10 ÷ 60 °C
50
1 ÷ 15 days
10
10 ÷ 60 °C
50
10 ÷ 60 °C
50
1 ÷ 15 days
5
10 ÷ 60 °C
50
10 ÷ 60 °C
20
Service setting manual