Operating Instructions
– When installing the electrical socket, select an
DE
industrial electrical outlet with the highest
possible power available (adapted to the
EN
domestic electric installation) and have it put into
FR
operation by a qualified electrician.
– Where technically possible and legally
IT
permissible, the electric installation must be
dimensioned in such a way that the maximum
ES
nominal power of the electrical socket used
PT
is available for charging the vehicle.
– In order to fully exploit the performance of
NL
the charger and to ensure fast vehicle charging,
use either NEMA electrical sockets with the
SV
highest possible current rating appropriate for
the power plug or industrial electrical outlets
FI
according to IEC 60309.
DA
– When charging the high-voltage battery via the
domestic electrical outlet/industrial electrical
NO
outlet, the electrical installation may be loaded to
its maximum capacity. Porsche recommends
EL
having electrical installations used for charging
regularly checked by a qualified electrician.
CZ
Ask a qualified electrician which inspection
HU
intervals are appropriate for your installation.
– On delivery, the charging current is automatically
PL
limited to prevent overheating of the electrical
installation. Have a qualified electrician put the
HR
charger into operation and set the charging
current limiting in accordance with to the
SK
domestic installation.
f Refer to chapter "Charging Current Limiting"
SL
on page 29.
ET
LT
LV
RO
BG
24
Intended Purpose
Charger for operation in charging mode 2 for
charging vehicles with high-voltage batteries, which
meet the generally applicable standards and
directives for electric vehicles.
Key to Pictograms
Depending on the country, various pictograms may
be attached to the charger.
Operate the charger within a
temperature range from –30 °C
to +50 °C.
The charger should not be
operated at altitudes of more
than 4,000 m above sea level.
The charger is equipped with
a non-switched ground lead.
The charger is equipped with
a switched ground lead.
Dispose of the charger in
compliance with all applicable
disposal regulations.
Do not use extension cables or
cable reels.
Do not use (travel) adapters.
Do not use multi-outlet power
strips.
Do not use charging cables with
faulty electronics or connecting
lines.
Risk of electric shock due to
improper use
Observe the operating instructions
provided, particularly the warnings
and safety instructions.
The surface of the charger can
become very hot.
Do not operate the charger in
non-earthed mains supply
systems (e.g. IT networks).
Only operate the charger in
earthed mains supply systems.
Only operate the charger in
single-phase supply systems.