ANALOG INPUT 1
VALUE [ 16] –
FALSE
(1)
BREAK [ 18] –
0.00%
0.00%
(17)
100.00% – [ 14] SCALE
–
0.00%
0.00% – [ 15] OFFSET
–
0.00% – [132] INPUT C
0..+10V – [ 13] TYPE
–
A+B+C – [134] TYPE
FALSE – [ 12] BREAK ENABLE
–
0.00% – [ 17] BREAK VALUE
–
ANALOG INPUT 2
VALUE [ 25] –
FALSE
(2)
BREAK [ 27] –
0.00%
(18)
100.00% – [ 23] SCALE
–
0.00% – [ 24] OFFSET
–
0..+10V – [ 22] TYPE
–
FALSE – [ 21] BREAK ENABLE
–
0.00% – [ 26] BREAK VALUE
–
FALSE – [327] RAISE INPUT
FALSE – [328] LOWER INPUT
10.0s – [326] RAMP RATE
DIGITAL INPUT 1
100.00% – [330] MAX VALUE
VALUE [ 31] –
FALSE
(3)
-100.00% – [329] MIN VALUE
FALSE – [ 30] INVERT
–
0.00% – [331] RESET VALUE
FALSE – [332] RESET
DIGITAL INPUT 2
VALUE [ 34] –
FALSE
(4)
FALSE – [ 33] INVERT
–
DIGITAL INPUT 3
VALUE [ 37] –
FALSE
(5)
FALSE – [ 36] INVERT
–
DIGITAL INPUT 4
VALUE [ 40] –
FALSE
(6)
TRUE – [ 39] INVERT
–
DIGITAL INPUT 5
VALUE [ 43] –
FALSE
FALSE – [ 42] INVERT
–
(7)
FALSE
FALSE
FALSE – [293]
FALSE
TRUE – [276]
TRUE – [277]
ANALOG DIGIN 1
TRUE – [278]
VALUE [ 90] –
FALSE
FALSE – [294]
FALSE – [ 89] INVERT
–
FALSE
70.00% – [ 91] LEVEL
–
TRUE – [290]
10.00% – [ 92] HYSTERISIS
–
FALSE – [283]
ANALOG DIGIN 2
VALUE [95] – FALSE
FALSE – [94] INVERT
–
70.00% – [96] LEVEL
–
10.00% – [97] HYSTERISIS
–
605 Series Frequency Inverter - HA463544
VALUE FUNC 1
OUTPUT [133] –
0.00%
(8)
– [130] INPUT A
–
– [131] INPUT B
–
–
0.00%
–
0.0Hz – [341] BAND 1
0.0Hz – [342] FREQUENCY 1
0.0Hz – [680] BAND 2
0.0Hz – [343] FREQUENCY 2
0.0Hz – [681] BAND 3
0.0Hz – [344] FREQUENCY 3
0.0Hz – [682] BAND 4
0.0Hz – [345] FREQUENCY 4
RAISE/LOWER
OUTPUT [325] – 0.00%
–
–
FALSE
–
FALSE
–
FALSE
–
–
–
105.00% – [237] I*t THRESHOLD
60s – [238] I*t TIME
150.00% – [239] I*t UPPER LIMIT
SEQUENCING LOGIC
TRIPPED [289] –
FALSE
100.00% – [240] STALL LIMIT
(12)
600.0s – [241] STALL TIME
RUNNING [285] –
FALSE
(13)
JOGGING [302] –
FALSE
STOPPING [303] –
FALSE
OUTPUT CONTACTOR [286] –
FALSE
SWITCH ON ENABLE [288] –
FALSE
SWITCHED ON [306] –
TRUE
READY [287] –
FALSE
SYSTEM RESET [305] –
TRUE
0600 – [231] DISABLED TRIPS
MAIN SEQ STATE [301] – NOT READY
REMOTE REV OUT [296] –
FALSE
(11)
HEALTHY [274] –
FALSE
– [291]
RUN FWD
–
– [292]
RUN REV
–
/STOP
–
– [280]
JOG
–
DRIVE ENABLE
–
/FAST STOP
–
/COAST STOP
–
REMOTE REVERSE –
– [282]
REM TRIP RESET
–
TRIP RST BY RUN –
POWER UP START –
SKIP FREQUENCIES
MINIMUM SPEED
OUTPUT [346] –
0.0%
(9)
OUTPUT Hz [363] – 0.0Hz
0.00%
– [336] INPUT
INPUT Hz [362] – 0.0Hz
-100.00% – [337] MINIMUM
– [340] INPUT
–
PROP. W/MIN. – [338] MODE
–
–
–
–
–
–
–
–
I/O TRIPS
– [234] EXTERNAL TRIP
–
– [235] INPUT 1 BREAK
–
– [236] INPUT 2 BREAK
–
I*t TRIP
–
–
–
STALL TRIP
–
–
TRIPS STATUS
ACTIVE TRIPS [ 4] – 0000
WARNINGS [ 5] – 0000
FIRST TRIP [ 6] – NO TRIP
–
TRIPS HISTORY
TRIP 1 [NEWEST] [500] – NO TRIP
TRIP 2 [501] – NO TRIP
TRIP 3 [502] – NO TRIP
TRIP 4 [503] – NO TRIP
TRIP 5 [504] – NO TRIP
TRIP 6 [505] – NO TRIP
TRIP 7 [506] – NO TRIP
TRIP 8 [507] – NO TRIP
TRIP 9 [508] – NO TRIP
TRIP 10 [OLDEST] [509] – NO TRIP
142
REFERENCE
OUTPUT [335] –
0.00%
SPEED DEMAND [255] –
(10)
SPEED SETPOINT [254] – 0.00%
–
–
REVERSE [256] – FALSE
–
LOCAL SETPOINT [247] – 0.00%
LOCAL REVERSE [250] – FALSE
COMMS SETPOINT [269] – 0.00%
0.00%
– [245] REMOTE SETPOINT –
0.00% – [248] SPEED TRIM
–
100.00% – [252] MAX SPEED CLAMP –
-100.00% – [253] MIN SPEED CLAMP –
FALSE – [243] TRIM IN LOCAL
–
FALSE
– [249] REMOTE REVERSE –
SYSTEM RAMP
RAMPING [698] – FALSE
LINEAR – [244] RAMP TYPE
10.0s – [258] ACCEL RATE
10.0s – [259] DECEL RATE
10.0s – [267] SYMETRIC RATE
FALSE – [268] SYMETRIC MODE
FALSE – [260] RAMP HOLD
TRUE – [691] SRAMP CONTINUOUS –
10.00% – [692] SRAMP ACCEL
10.00% – [693] SRAMP DECEL
10.00% – [694] SRAMP JERK 1
10.00% – [695] SRAMP JERK 2
10.00% – [696] SRAMP JERK 3
10.00% – [697] SRAMP JERK 4
STOP
RAMPED – [279] RUN STOP MODE
–
10.0s – [263] STOP RATE
–
0.10% – [266] STOP ZERO SPEED –
0.500s – [284] STOP DELAY
–
RAMPED – [304] FAST STOP MODE –
30.0s – [275] FAST STOP LIMIT
–
0.1s – [264] FAST STOP RATE –
1200Hz/s – [126] FINAL STOP RATE –
JOG
10.00s – [246] SETPOINT
–
1.0s – [261] ACCEL RATE
–
1.0s – [262] DECEL RATE
–
16
Application Macros
ANALOG OUTPUT 1
0.0 %
0.00%
– [ 45] VALUE
–
(14)
100.00% – [ 46] SCALE
–
0.00% – [ 47] OFFSET
–
TRUE – [ 48] ABS
–
0..+10V – [ 49] TYPE
–
SETPOINT SCALE
OUTPUT [ 59] – 0.00% lf
0.00%
– [ 58] INPUT
–
(15)
* 50.0Hz – [ 57] MAX SPEED
–
–
–
ZERO SPEED
–
AT ZERO SPEED [360] –
FALSE
–
– [358] INPUT
–
(16)
–
0.50%
– [357] LEVEL
–
–
– [359] BAND
–
0.00%
–
–
–
–
–
–
DIGITAL OUTPUT 1
FALSE
– [ 52] VALUE
–
TRUE – [ 51] INVERT
–
DIGITAL OUTPUT 2
FALSE
– [ 55] VALUE
–
FALSE – [ 54] INVERT
–
Macro 2