Problem/possible cause
The Signal indicator does not illuminate.
The Error indicator is on.
Automatic data transmission was interrupted or
missed at 12 pm (eg, no signal,
RCM/ventilation device disconnected or
powered off).
If the problem cannot be solved, contact your care provider or ResMed representative.
Technical specifications
Dimensions (H x W x L)
Weight
Power supply unit (PSU)
Housing construction
Environmental conditions
Operating temperature:
Operating humidity:
Operating altitude:
Storage and transport temperature:
Storage and transport humidity:
Electromagnetic compatibility
IEC 60601-1 classification
Compatible software versions
Wireless module
Declaration of Conformity (DoC to the
Radio Equipment Directive)
Solution
the ventilation device.
Change the position of RCM.
Check that you have network reception.
Ensure that RCM is ideally 30 cm away from the ventilation device or
other electrical equipment.
Switch RCM off, then on again, to see if this removes the error. If the
Error indicator displays again, contact your care provider or ResMed
representative.
Re-establish the connection between RCM, ventilation device, and
AirView (refer to the Setup section). Automatic data transmission will
resume to send any outstanding data.
RCM only: 134 mm x 44 mm x 150 mm
The stand will add 3 mm to the height and 6 mm to the width.
RCM only: 280 g
The stand will add 30 g and the wall mount will add 10 g.
AC 100–240 V, 0.35–0.70 A, 50–60 Hz
DC 24 V, 1.25 A
Cable length 1.8 m
Class II, suitable for continuous operation
Typical power consumption; <3W
Maximum power consumption: <5W
Flame retardant engineering thermoplastic and silicone
o
o
+0
C to +40
C
10%–95% non-condensing
Sea level to 3000 m
o
o
--25
C to +70
C
10%–95% non-condensing
Product complies with all applicable electromagnetic compatibility
requirements (EMC) according to IEC60601-1-2, for residential, commercial and
light industry environments. It is recommended that mobile communication
devices are kept at least 12" (30 cm) away from the device.
Information regarding the electromagnetic emissions and immunity of this
ResMed device can be found on www.resmed.com/downloads/devices.
Non-transit operable, portable equipment
AirView: 4.1 or higher
Astral: SX544-0401 or higher
Stellar: SX483-0250 or higher
Technology used: 4G/2G
ResMed declares that the ResMed Connectivity Module (model 27202) is in
compliance with the essential requirements and other relevant provisions of
Directive 2014/53/EU (RED). A copy of the Declaration of Conformity (DoC) can
be found on Resmed.com/product support.