Introduction Of Cooling Air In Cooling Ramps; Memory; Adjusting The Firing Values During Firing; Error Messages - Rohde ST 630 Mode D'emploi

Masquer les pouces Voir aussi pour ST 630:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 93
8.3.3.

Introduction of cooling air in cooling ramps

NOTE
The introduction of cooling air using a blower or fan at a firing chamber temperature of
more than 600°C can damage the insulating material or heating elements.
⇒ Cold air may only be brought in at a temperature below 600°C.
⇒ The fan cooling system must never run during the firing process!
⇒ The cooling system is only switched on below 600°C when the kiln is in cooling mode and
⇒ The exhaust air opening must be open when a cooling blower or cooling fan is in
⇒ Early cooling is not recommended as this can have a negative impact on the ceramics,
The manufacturer assumes no liability for damaged insulation material or heating elements if the
instructions have not been followed.
8.3.4.

Memory

As soon as the controller is turned off, all programs and necessary data are saved and retained.
8.3.5.

Adjusting the firing values during firing

During the program, certain firing values can be changed using the controller:
g
Use the
key to select the desired parameter during the firing process.
The parameter is indicated accordingly in the course of the program on the graphical display by a flashing icon.
The firing value is shown on the main display and can be adjusted with the
The contents of the current segment or any segment still to be executed can be changed.
Firing will still carry on as normal while these changes are being made.
The controller will return to its normal running display 20 seconds after key presses cease (or immediately after
"END" is displayed).
Changes made to programs in this way are stored and are used for subsequent firings.
9.

Error messages

If the control unit detects a problem, the buzzer will sound and an error message will be displayed.
9.1.

Display screen

Display
Description
Main display
This error message will alternate with a display of the kiln temperature.
Segment display
Display of the respective segment number in which the error occurred.
9.2.

Reading error messages

Step
Activity
h
Press the
key to obtain more information on
1
the error.
h
Press the
key again to display the length of
2
time the error has been present.
is not being heated anymore!
operation.
glazes and the durability of the kiln lining and the service life of the heating elements.
74 / 317 - EN -
d
and
Remark
The first press will display the maximum temperature
reached in the firing.
The buzzer will mute.
f
keys in the usual way.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

St 632

Table des Matières