Segment
display
Graphical program operation display:
Value
1.1
1.2
2
3
⇒ There is only either one heating ramp (1.1) or one cooling ramp (1.2) per firing segment - never both!
6.4.2.
Example of a firing program to illustrate the firing segment
Example of a simple firing program to illustrate the firing segments and their values:
Firing segment
Firing segment values
Program delay or program start
0
delay (see Section 8.1.3.)
Heating ramp (1.1)
1
Target temperature (2)
Soak time (3)
Heating ramp (1.1)
2
Soak temperature (2)
Soak time (3)
Cooling ramp (1.2)
3
Target temperature (2)
Soak time (3)
Cooling ramp (1.2)
4
Target temperature (2)
Soak time (3)
Gaphical program &
operation display
Meaning
Heating ramp
Cooling ramp
Soak Temperature (target temperature)
Soak time
Graphical program operation display
Description of the values
Program delay = 1 h (60 min)
⇒ The firing program starts with a delay.
(Factory-set to 00 hours 00 min.)
Heating at 250°C/h
Heating up to 500°C
Hold for 0 min
Heating at 0°C/h
Hold at 500°C
Hold for 60 min
Cooling at 125°C/h
Cool to 20°C
Hold for 0 min
Setting the value to "END" ends the firing program.
-
-
60 / 317 - EN -
3
1.2
1.1
2