2.5.
Plug pin assignment (ROHDE default)
2.5.1. CPC 14 connector (ST 630 only)
Single and multi-zone kilns without additional switch outputs (events) are connected by a CPC 14 connector.
Pin no.
X = Used
1
X
2
X
3
X
4
X
5
X
X
6
7
X
8
X
9
X
10
X
11
X
12
X
13
X
14
X
2.5.2.
CPC 19 connector (ST 632 only)
Multi-zone kilns with additional switch outputs (events) are connected by a CPC 19 connector.
Pin no.
X = Used
1
X
2
X
X
3
X
4
X
5
X
6
7
X
8
X
9
X
X
10
X
11
12
X
13
X
14
X
X
15
X
16
17
-
18
-
19
-
2.5.3.
Special Notes
•
Each switch output can switch a maximum of 250-300 mA at 230 V.
•
A relay must be used at these outputs to switch loads.
•
The wiring of the mating CPC 14/19 socket can vary between kiln manufacturers! Non-observance can result
in damage to the controller and kiln.
Description
Thermocouple 1 +
Thermocouple 1 -
Thermocouple 2 +
Thermocouple 2 -
Thermocouple 3 +
Thermocouple 3 -
Zone 2 switch output
L1 feed 230 V AC
N feed
Zone 3 switch output
PE feed
Safety contactor switch output
Neutral conductor switch output
Zone 1 switch output
Description
Thermocouple 1 +
Thermocouple 1 -
Thermocouple 2 +
Thermocouple 2 -
Thermocouple 3 +
Thermocouple 3 -
Zone 2 switch output
L1 feed 230 V AC
N feed
Zone 3 switch output
PE feed
Safety contactor switch output
Neutral conductor switch output
Zone 1 switch output
Additional switch output No. 1 (230 V)
Additional switch output No. 2 (230 V)
Not used
Not used
Not used
53 / 317 - EN -
Pin assignment
Pin assignment