Indicator
on the
Main display
left
00 : 15
END
h
g
*The keys
or
can also be held down for faster input.
Note:
• It is possible to exit programming mode without performing all of the steps described above. To do this, wait 20
seconds without pressing a key and the controller will revert to the idle display. All changes are automatically
applied and saved immediately.
• Alternatively, exit the programming mode with the
made are automatically saved, however.
h
g
• The
or
keys can be used to cycle through the programming steps to correct errors or to exit
programming mode.
• The switch output (event) can be added or deselected by pressing the switch output (event) key while
programming the heating ramp, cooling ramp and soak time (see Section 7.).
Heating
zone display
Meaning
on the right
Soak time
Indicator in the
segment display
End program
input
j
63 / 317 - EN -
Description
•
The next push of the
soak period in "hours:minutes".
•
This can be altered in the range 00:00 to
99:59 with the
•
The soak period indicator on the graphical
display will flash.
Notes:
⇒ To program the additional switch outputs
1 & 2 see section 7.4.
The next press of the
segment number digit and firing values for the
next segment can be entered.
⇒ The entry of the values is carried out in the
same way as for the entry of the first
segment.
•
To mark the end of the program, push the
f
key until "END" appears in the main
display.
•
To end the program input, press the
key.
Notes:
⇒ Program input is also automatically
terminated if the maximum number of
segments have been entered.
⇒ If "END" is not entered in the last segment,
the controller issues the error message
"Error P" when the program starts.
key and start the firing process immediately; all changes
g
key displays the
d
f
and
keys.
g
key increments the
g