Type 8202/8222
Fig. 10: Mounting the electronic module to the holder, without fluid
(8202)
Mounting the display module
Calibrate the transmitter.
Installation
Fasten the electronic module
and the holder together by
tightening the nut. Tighten the
G 2'' nut by hand only, until it
stops turning, to ensure good
electrical contact.
8.
insTAllATion
8.1.
safety instructions
Warning
risk of injury due to non-conforming installation.
• The electrical and fluid installation can only be carried out by
qualified and skilled staff with the appropriate tools.
• Install appropriate safety devices (correctly rated fuse and/or
circuit-breaker).
• Respect the assembly instructions for the fitting used.
risk of injury due to unintentional switch on of power supply
or uncontrolled restarting of the installation.
• Avoid unintentional activation of the installation.
• Guarantee a set or controlled restarting of the process sub-
sequent to any intervention on the device.
English
19