NOTE: BLACK OUT ALARM
This alarm indicates a lack of power.
When the cabinet is connected again to power, it completes the cycle to the end.
Example:
-23 days and 7 hours to the end of cycle
-lack of power for 5 hours (Black out alarm with its duration – 5 hours – is stored)
-once the cabinet is connected again to power, it will complete the program with the remaining 23 days and 7 hours.
LABEL
High temp. room
Al.
Low temp. room Al
Black out Al.
Room probe Al.
Evap. probe Al.
Low temp. evapo-
rator Al
Cond. probe Al.
High cond. temp.
Al.
Dirty condenser
Al.
Humidity probe
Al.
Open door Al.
Comp. use Al.
p
Print 10
Allowance to print the alarms occurred or working data (only when a printer is provided).
-Press
,
-Scroll the main menu with
-Confirm with
-Scroll the print options with
a) ALARMS: allow to print all occurred alarms.
Press
for 3 seconds for data printing.
Print
Alarm
b) DAILY: allows printing samples of working data during a day.
Print
Daily
PROBLEM
Temperature inside the cabinet is
above the alarm mark
Temperature inside the cabinet is
below the alarm mark
Lack of power to the cabinet
Broken room probe
Broken evaporator probe
The evaporator temperature is below
the alarm mark
Broken condenser probe
The condenser temperature is above
the alarm mark
The condenser is dirty
Broken humidity probe
Door opened
The compressor has worked for too
long during a day
until you find the Menu 10 Print.
:
SEASONING
ALARMS LIST
ACTION
Check the operation of the refrigerant circuit
Check the operation of the heating circuit
Check the power line towards the cabinet
Replace the room probe
Replace the evaporator probe
Check the operation of evaporator fan
Replace the condenser probe
Check the operation of condenser fan
Accurately clean the condenser
Replace humidity probe
Close the door. Do not leave the door open for long time (20m)
Check the operation of refrigerating unit
40