FAULT POSSIBLE CAUSE
Appliance does not switch on
Refrigeration unit does not start
Refrigeration unit runs con stantly
but does not reach
set temperature
Refrigeration unit does not
cut out at set temperature
Build up of ice on evaporator
Water or ice deposits
in the drip tray
Section 7 DIAGNOSTICS
The following problems may occur as indicated in the table below
ACTION
switch set to - O -
power failure
other
set temperature has been reached
defrosting cycle in progress
control panel fault
other
room temperature too high
condenser dirty
refrigerant needs recharging
condenser fan not running
door seals are not efficient
are not obstructing doors
evaporator is coated with ice
defrost valve is open
control panel fault
E1 temperature sensor defective
improper use
control panel fault
E2 defrost sensor defective
drain outlet is clogged
appliance not level
SEASONING
set switch to - I -
check plug, socket, fuses, electrical line
contact service department
set new temperature
wait for cycle end, switch off and then on again
contact service department
contact service department
provide better ventilation of room
clean condenser
contact service department
contact service department
check seals / make sure refrigerator contents
defrost manually
contact service department
contact service department
contact service department
see headings 3.4
contact service department
contact service department
clean drain and drain outlet
see heading 3.2
30
RIMEDIO