Displays In Operating Mode - SICK IN3000 Direct Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Operating instructions
IN3000 Direct
Tab. 5:
LED displays in
operating mode
8014173/YIJ3/2016-04-18
Subject to change without notice
Product description
3.5

Displays in operating mode

The IN3000 Direct safety switch has two bi-color LEDs.
The LEDs illuminate green (Power LED) and/or yellow
(signal LED).
LED status
Operational status
Yellow (Signal)
No supply voltage
Green (Power)
Yellow (Signal)
Undervoltage
Green (Power)
Yellow (Signal)
Overvoltage
Green (Power)
Sensor error:
see chapter 7 "Fault
diagnosis"
Yellow (Signal)
Supply voltage
Green (Power)
present, actuating
element is in the
safe switch off
distance: s
Actuating element
Yellow (Signal)
Green (Power)
inside the enable
zone
Actuating element
inside the near range
zone
Meaning of the symbols:
The LED is illuminated constantly.
The LED is flashing (1.65 Hz).
The LED flashes quickly (4.85 Hz).
The LED is off.
Signal LED: yellow
Power LED: green
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Outputs
Both outputs
switched off
Both outputs
switched off
One output or
both outputs
switched off
Both outputs
switched off
ar
Both outputs
enabled
Output A2 is
switched off
Chapter 3
OUT1 OUT2
0
0
1
0
0
0
0
0
0
1
1
0
0
0
0
0
1
1
1
0