Chapter 2
WARNING
56
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
On safety
Note on the classification of the device according to
EN 60947-5-2:
The IN30-E0407K safety switch corresponds to
classification I2A12SP2 for non-flush mounting.
The IN30-E0305K safety switch corresponds to
classification I2A18SP2 for non-flush mounting.
The IN30-E0306K safety switch corresponds to
classification I1A18SP2 for flush mounting.
The IN30-E0208K safety switch corresponds to
classification I2A30SP2 for non-flush mounting.
Safety switches are not allowed to be bypassed,
turned away, removed or made ineffective in any
other manner. Their contacts must not be bridged.
The inductive safety switches react to metal objects.
Other metal objects that are not to trigger the safety
function must never reach the sensing face of the
safety switch. Suitable measures must be taken to
prevent this situation arising, see chapter 4
"Mounting".
Please observe the installation features as per
EN ISO 14119.
Damaged devices must be replaced.
Operating instructions
IN3000 Direct
8014173/YIJ3/2016-04-18
Subject to change without notice