SICK IN3000 Direct Mode D'emploi page 83

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Operating instructions
IN3000 Direct
8014173/YIJ3/2016-04-18
Subject to change without notice
Technical specifications
Parameter
Response time
Response time to safety
request (removal from the
enable zone)
IN30-E0407K
IN30-E0305K
IN30-E0306K
IN30-E0208K
Response time on
approach to the enable
zone (enable time)
Risk time (error response
time)
IN30-E0407K
IN30-E0305K
IN30-E0306K
IN30-E0208K
EMC/vibration, shock
Operating data
Response range/enable
zone for steel (FE360)
IN30-E0407K
IN30-E0305K
IN30-E0306K
IN30-E0208K
Safe switch off distance s
IN30-E0407K
IN30-E0305K
IN30-E0306K
IN30-E0208K
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Value
C 1 ms
C 10 ms
C 1 ms
C 20 ms
C 30 ms
as per EN 60 947-5-2
0.5 mm ... 4 mm
1 mm ... 8 mm
1 mm ... 5 mm
1 mm ... 15 mm
ar
> 6 mm
> 12 mm
> 7 mm
> 22 mm
Chapter 9
83

Publicité

Table des Matières
loading

Table des Matières