11. DIAGNOSTICS

11.1. Operating codes display

Code
Description
C1
Awaiting command
C2
Gate opening
C3
Awaiting gate
closure
C4
Gate closing
C6
Detection in pro-
gress for cell safety
C7
Detection in
progress for safety
edge safety
C8
Detection in pro-
gress for program-
mable safety
C9
Detection in pro-
gress for emergency
stop safety
C12
Reinjecting current
C13
Safety device auto-
test in progress
C14
Permanent complete
opening wire control
input
C15
Permanent pedes-
trian opening wire
control input
BUS cell program-
C16
ming refused
Cc1
9.6 V power supply
Cu1
24 V power supply
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.
Comments
Automatic closing time delay P02, P04 or
P05 in progress.
Displayed during a movement request or
during movement when detection is in
progress on the safety input.
The display appears for as long as detec-
tion is in progress on the safety input.
Displayed while the autotest is running
on the safety devices.
Indicates that the complete opening wire
control input is permanently activated
(contact closed). Commands coming
from the radio remote controls are then
disabled.
Indicates that the pedestrian opening
wire control input is permanently activat-
ed (contact closed). Commands coming
from the radio remote controls are then
disabled.
Check that the BUS cells (wiring, align-
ment, etc.) are operating correctly
Displayed during operation with 9.6 V
backup battery
Displayed during operation with 24 V
backup battery or solar supply

11.2. Programming codes display

Code
Description
H0
Awaiting setting
Hc1
Awaiting setting +
9.6 V power supply
Hu1
Awaiting setting + 24
V power supply
H1
Awaiting start of
auto-programming
H2
Auto-programming
mode - opening
H4
Auto-programming
mode - closing
F0
Awaiting remote
control memorisa-
tion for operation in
complete opening
mode
F1
Awaiting remote
control memorisa-
tion for operation in
pedestrian opening
mode
F2
Awaiting remote
control memori-
sation for remote
lighting control
F3
Awaiting remote
control memori-
sation for auxiliary
output control
Comments
Pressing and holding the "SET" button
for 2 seconds starts auto-programming
mode.
Displayed during operation with 9.6 V
backup battery.
Displayed during operation with 24 V
backup battery or solar power supply.
Pressing the "OK" button starts the
auto-programming cycle.
Pressing the "+" or "-" button allows
the motor to be controlled in forced
operation mode.
Pressing a button on the remote control
allocates this button to the motor com-
plete opening control.
Pressing "PROG" once more switches
to "awaiting remote control memorisa-
tion for operation in pedestrian opening
mode: F1".
Pressing a button on the remote control
allocates this button to the motor pedes-
trian opening control.
Pressing "PROG" once more switches
to "awaiting remote lighting control
memorisation: F2".
Pressing a button on the remote control
allocates this button to the remote
lighting control.
Pressing "PROG" once more switches
to "awaiting auxiliary output control
memorisation: F3".
Pressing a button on the remote control
allocates this button to the remote
lighting control.
Pressing "PROG" once more switches to
"awaiting remote control memorisation
for operation in complete opening mode:
F0".