The glass must be correctly closed and locked in
position by turning the stop couter-clockwise.
INSTRUCTIONS
V.
MAINTENANCE
14. REMINDERS FOR THE MAINTENANCE
TECHNICIAN
THE MANUFACTURER WILL NOT BE
LIABLE FOR ANY DAMAGE OR INJURY
RESULTING
OBSERVING THE FOLLOWING RULES.
Identify the specific appliance model. The model
number is detailed on the packing and on the
appliance dataplate.
The appliance must be installed in a well-ventilated
room.
Do not obstruct any air vents or drains present on the
appliance.
Do not tamper with appliance components.
Appliance maintenance and conversion to a different
type of gas must be carried out by qualified
technicians authorized by the manufacturer, in
compliance with current safety standards and the
instructions in this manual.

15. CONVERSION TO ANOTHER TYPE OF GAS

See Chapter " Instructions for installation ".

16. COMMISSIONING

See Chapter " Instructions for installation ".

17. TROUBLESHOOTING

OVEN
THE OVEN DOES NOT START
Check that the multiple pole switch is closed and
-
there is mains voltage.
FOR
FROM
FAILURE
TO
22
Check that the gas shut-off cock upstream of the
-
appliance is open.
- Check integrity of the oven protection fuses.
- Ensure the oven door is correctly closed.
Check to have correctly set the cooking cycle
-
parameters.
- Ascertain the oven is not in error.
THE FAN STOPS DURING FUNCTIONING.
Switch-off the oven and wait for the motor thermal
-
protection to automatically reset.
- Ensure that the cooling inlets are not obstructed.
WATER DOES NOT FLOW INTO THE HUMIDIFIER
TUBES.
- Check that the water shut-off cock is open.
THE IMPELLER DOES NOT ROTATE.
Check the water pressure, it must be higher than 150
kPa.

18. REPLACING COMPONENTS

REMINDERS FOR REPLACING COMPONENTS
SHUT THE GAS SHUT-OFF VALVE
AND/OR SWITCH THE APPLIANCE OFF
AT THE MAIN SWITCH INSTALLED
UPSTREAM.
AFTER REPLACING A GAS SYSTEM
COMPONENT, CHECK FOR GAS LEAKS
AT CONNECTION POINTS.
DISCONNECT
ELECTRIC
BEFORE
OPERATION.
AFTER REPLACING AN ELECTRICAL
SYSTEM COMPONENT, CHECK IT IS
CORRECTLY WIRED.
OVEN
SOSTITUTION OF THE LAMP
- Open the oven door.
- Remove the protection
- Remove and replace the component.
Reassemble all parts. For assembly, proceed in
-
reverse order.
SOSTITUTION OF THE ELECTRICAL COMPONENTS
- Remove right panel
THE
APPLIANCE
SUPPLY,
IF
PRESENT,
CARRYING
OUT
ANY