4. REFERENCE STANDARDS AND LAWS

Install the appliance in accordance with the safety
standards in force in the country.

5. UNPACKING

Check the state of the packing and in the event of
damage, ask the delivery person to inspect the
goods.
Remove the packing.
Remove the protective film from the outer panels.
Use a suitable solvent to remove any residual
adhesive from the panels.

6. POSITIONING

The overall dimensions of the appliance and the
position of connections are given on the installation
diagram at the end of this manual.
The appliance can be installed singly or in
combination with other appliances in the same
product range.
The appliance is not suitable for integrated
installation.
Position the appliance at least 10 cm from adjacent
walls.
If the appliance is to be be placed near walls,
dividers, kitchen furniture, decorative elements etc.
this must be made of non-combustible materials
Otherwise, they must be covered with suitable non-
combustible heat insulating materials.
Level the appliance by means of the height-
adjustable feet
APPLIANCE ASSEMBLY WITH BASE, BRIDGE AND
CANTILEVER SOLUTIONS
Follow the instructions provided with the type of
support utilized.
FUMES EXHAUST SYSTEM
Create a fumes exhaust system based on the " Type "
of appliance. The " Type " is stated on the appliance
dataplate.
" A1 " TYPE APPLIANCE
Position the "A1" type appliance below an extractor
hood to ensure smoke and fumes generated by
cooking are removed.
" B21 " TYPE APPLIANCE
Position the "B21" type appliance below an extractor
hood.
" B11 " TYPE APPLIANCE
Fit the "B11" type appliance with a suitable fl ue,
available from the appliance manufacturer. Follow
the assembly instructions provided with the flue.
Connect the flue to a 150/155 mm diameter hose,
heat resistant to 300°C.
Vent to the outside or into an effi cient fl ue. The
hose length must not exceed 3 metres.

7. CONNECTIONS

The position and dimensions of connections are given
in the installation diagram at the end of this manual.
CONNECTION TO THE GAS SUPPLY
Check that the appliance is designed to operate with
the type of gas supply present on site. Check the
information given on the decals on the packing and
appliance.
Convert the appliance to the local gas type, if
necessary. Follow the instructions at the next
paragraph "Conversion to a different type of gas".
On top appliances a rear connection is also available.
Remove the plug present and screw it tightly onto
the front connector.
A rapid-action gas shut-off valve must be fitted
upstream of the appliance in an easily accessible
position.
Do not use connection pipes having a diameter
smaller than that of the appliance' s gas connector.
Once the appliance has been installed, check for gas
leaks at the connection points.
ELECTRICAL CONNECTIONS
Check if the appliance is designed to operate at the
voltage and frequency of the power supply present
on site. Check the details given on the appliance
dataplate and plaque near the terminal board.
Install upstream of the equipment in an easily
accessible place, an all-pole disconnecting device
with a contact gap of allowing full disconnection
under the conditions of overvoltage category III.