MF1 Setup
Threshold
Position
129
MF1 Setup
Hysteresis
130
MF1 Setup
Threshold
Velocity
131
MF1 Setup
Velocity Sign
132
MF1 Setup
Static Preset
Attribute
Name
133
MF2 Setup
Active Level
134
MF3 Setup
Function
135
MF2 Setup
Service
136
MF2 Setup
Service
137
MF2 Setup
Service
138
MF2 Setup
Service
139
MF2 Setup
Service
140
MF2 Setup
Service
141
MF2 Setup
Threshold
Position
142
MF2 Setup
Hysteresis
143
MF2 Setup
Threshold
Velocity
144
MF2 Setup
© SICK AG • Subject to change without notice • 8019720/ZVZ7/2018-03-22
Operating instructions Distance measuring device DL100 – EtherNet/IP
DINT
Range: -300 – 300m
UDINT
Range: 1mm – 300m
DINT
Range: 50mm/s – ...mm/s
USINT
Threshold velocity can be exceeded in one or both directions.
- (0)
+ (1)
+/- (2, default)
DINT
Preset value that will be applied if attribute 121 is set to
INPUT_PRESET_STATIC.
Range: -300 – 300m
MF2 Configuration
Type
ENUM
Active level of MF2. Can either be HIGH (0) or LOW (1).
ENUM
Function of MF2. Can be one of:
OUTPUT_DISTANCE_THRESHOLD (0)
MF2 is an output and is toggled when attribute 10 exceeds/falls
under attribute 141/142.
OUTPUT_VELOCITY_THRESHOLD (1)
MF2 is an output and is toggled when attribute 24 exceeds/falls
under attribute 143/144.
OUTPUT_SERVICE
MF2 is an output and is toggled by a logical OR over all active
service attributes 135-140.
BOOL
Plausibility Warning and Error
Disabled (0, default), Enabled (1):
If disabled, Error and Warning bits are not considered when
attribute 134 is set to OUTPUT_SERVICE.
BOOL
Level Warning and Error
Disabled (0, default), Enabled (1):
If disabled, Error and Warning bits are not considered when
attribute 134 is set to OUTPUT_SERVICE.
BOOL
Laser Warning and Error
Disabled (0, default), Enabled (1):
If disabled, Error and Warning bits are not considered when
attribute 134 is set to OUTPUT_SERVICE.
BOOL
Temperature Warning and Error
Disabled (0, default), Enabled (1):
If disabled, Error and Warning bits are not considered when
attribute 134 is set to OUTPUT_SERVICE.
BOOL
Device not ready
Disabled (0, default), Enabled (1):
If disabled, bit is not considered when attribute 134 is set to
OUTPUT_SERVICE.
BOOL
Heater active
Disabled (0, default), Enabled (1):
If disabled, bit is not considered when attribute 134 is set to
OUTPUT_SERVICE.
DINT
Range: -300 – 300m
UDINT
Range: 1mm – 300m
DINT
Range: 50mm/s – ...mm/s
USINT
Threshold velocity can be exceeded in one or both directions.