Apply A Static Preset - SICK DL100 Pro Notice D'instructions

Masquer les pouces Voir aussi pour DL100 Pro:
Table des Matières

Publicité

2.1.1. Apply a static preset

Note: Attribute 105 can only be written using implicit messaging
As implicit messaging is not supported by the tool we will write attribute 19 via explicit
messaging.
Set the data field to 0xe8030000 to apply a preset to 1000 (still using mm resolution)
Observe that the display will show 1000mm
Write 0x01 to attribute 106 to reset this preset
Note: Attribute 106 monitors 0-1 transitions. Thus, you might need to write 0x00 in case you have
previously written 0x01.
© SICK AG • Subject to change without notice • 8019720/ZVZ7/2018-03-22
Operating instructions Distance measuring device DL100 – EtherNet/IP
83