Guide rail
Puck
Fig. 9:
Aligning the puck
NOTE!
Damage to the PCB or malfunction!
▶ Ensure that the puck lies flat on the guide rail.
→
Push Type 8692/8693 without turning it onto the actuator until no
gap is visible on the form seal.
NOTE!
To comply with the degree of protection IP65 / IP67, do not
fasten the fastening screws too tightly.
▶ Maximum tightening torque: 1.5 Nm.
→
Attach Type 8692/8693 to the actuator using the two side fas-
tening screws. In doing so, tighten the screws only hand-tight
(max. tightening torque: 1.5 Nm).
18
English
Type 8692, 8693
Installation
10.4 Installation on process valves, series
26xx and 27xx
The installation of the switch spindle is described in the
operating instructions for Type 8692/8693. You can find the
instructions on the Bürkert homepage.
→
Place Type 8692/8693 onto the actuator. In doing so, align the
puck of the actuator with the guide rail of Type 8692/8693
(see "Fig. 10").
Guide rail
Puck
Fig. 10: Aligning the puck
NOTE!
Damage to the PCB or malfunction!
▶ Ensure that the puck lies flat on the guide rail.
→
Press Type 8692/8693 all the way down as far as the actuator and
turn it into the required position.