Extra Control Panel; Operating Instructions For H1 Pro - Tylo Steam Pro Instructions D'installation Et D'utilisation

Générateur de vapeur
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
The control panel can also be connected to other items of equipment that transmit an impulse or to constant contact switches.
Explanation of the function with momentary/constant contact: The control panel starts (ON) and stops (OFF) each time a switch
is pressed or a short impulse is transmitted between terminals (+)19 and (-)20 in the control panel, regardless of whether or not
the panel is locked. The control panel is operational only for the length of time that has been programmed in the initial set-up. A
constant contact switch in a continuous circuit has the same function when the connection is made or broken.
Terminal (-)21 can be used to indicate, for example, whether bathing guests are able to see the status of the control panel (in-
built in the Tylö external switch/momentary on/off switch). When the steam generator is started using an external switch, this is
indicated by the fact that the diode on the external switch lights up. If the steam generator is programmed to start later or is in
standby mode, this is indicated by a flashing diode. When the control panel is OFF, the diode is not lit. The indication function is
connected between terminals (+)19 and (-)21, (12V/DC max 1.2W 100mA).

4.2 Extra control panel

It is possible to connect optional extra control panels (h1 PRO) serially from terminal A and B on the steam generator's circuit
board to terminal A and B respectively on the extra control panel. Current is connected from terminal (+)11 and (-)12 on the
steam generator's circuit board to terminal (+)11 and (-)12 respectively on the extra control panel. See Wiring diagram 14.
Before installing an extra control panel, Steam Pro must first be disconnected from the power supply. After the extra control
panel has been connected, the power supply can be reconnected and the system is ready for use. All the control panels
connected work in parallel: in principle, this means that a selection made on any of the control panels activates the same
selection on all of the other units that are linked together.
However, certain individual settings that do not affect the operation of the Steam Pro can be made separately on each panel:
-
Automatic key-lock ON/OFF.
-
Code lock ON/OFF.
-
Sleep mode setting
-
Vibration ON/OFF.
11
10
Figure 1. Basic menu h1 Pro
Explanation of symbols:
1.
On/Off
2.
Temperature
3.
Program start time
4.
Settings menu
5.
Status display – Indicates the status of certain functions (see 12, 13, 14 and 15)
6.
Up – One step up in the menu or one step up in the value entered
7.
Lighting – Switches lighting on/off in the sauna/steam room
8.
OK – Confirms selection
9.
Down – One step down in the menu or one step down in the value entered
10. Back – One step back in the menu tree or one step back when entering values
11. Home – Returns you to the basic menu (Figure 1)
12. Indicates that the sauna/steam generator is on
13. Indicates that h1 is programmed to start at some later point in time
14. Indicates that the lighting is on
15. Indicates that the panel is locked

5. Operating instructions for h1 Pro

1
2
3
4
5
6
7
8
9
12
13
14
15
17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

A1899

Table des Matières