5.7 Messages
Message
"Is the tank cleaned?"
"Cleanup in progress."
6.1 Inspecting the tank
To inspect the tank, proceed as follows:
1.
Use the main switch to disconnect the equipment
from the electricity supply.
2.
Loosen the locking screws that hold the front
casing and remove the metal plates.
4.
Free the rotating mechanism by lifting the locking
pin and rotate the tank to remove it.
20
Comment
The specified interval
between cleanups has
elapsed
Cleaning process in
progress.
6. Servicing Tylö Steam Pro
Locking
screws
Main switch
Locking
screws
Locking
pin
System behaviour
Notifies user when the
time has elapsed and
each time the system
starts up, if the user has
not cleaned the tank.
Notifies user when he/she
tries to turn on the sauna
while cleanup is in
progress.
3.
Open the hose clip to loosen the upper and lower
bellows.
5.
Open the clamping band.
6.
Lift off the top half off the tank.
7.
When reassembling, make sure that there is no
damage to the seal between the two halves of the
tank. If necessary, replace the seal.
Action
Tank service and then
press "Yes".
Sauna will not start.
Hose clip
Hose clip
Clamping
band