Cleaning
Cleaning time – After a specified number of hours a message will appear with a reminder to clean the tank. This is where
you set the number of hours between cleaning. Use the number of hours indicated by EASY TEST. If no
reminder is needed, set 0 hours.
Last cleaned – Indicates the time that has elapsed since the equipment was last cleaned. "---" means that the equipment
has not been cleaned.
Tank emptying – Number of hours between automatic tank emptying when the steam bath is operational. Default value is
4 hours.
Diagnostics
Relay control – Only for Tylö service technicians.
Extra relay control – Only for Tylö service technicians.
System status – Shows current status for water level, water temperature, steam bath temperature, electrode value for
level indicator, running time, software/hardware version and product ID.
Heater-net node list – Shows which products are connected to the system.
Error log – Any system errors are logged here.
Factory reset
Enter code 421 to reset the control panel to the factory default settings.

5.6 Error messages

Message
"Sauna temperature sensor
failure."
"Tank temperature sensor failure."
"Electronics in heater
overheated".
"Fatal error! Unplug power, and
contact service".
"Electrode failure! Contact
service."
"Lost contact with control panel."
"Lost contact with
temperature/humidity sensor."
"Tank overheated."
"Hardware error. Contact service"
"Power outage. Set time."
"Lost contact with fragrance
pump."
Code
Comment
0x0001
NTC temperature sensor
in the sauna is either not
connected or has
shorted.
0x0002
NTC temperature sensor
in the sauna is either not
connected or has
shorted.
0x0003
Temperature on the RCB
PCB is greater than
70˚C.
0x0004
The outputs to the relays
do not match the inputs
from the contactors.
Might be welded relays.
0x0005
The tank has overfilled
three times.
0x0006
The system has
restarted because the
RCB was not able to
communicate with one of
the control panels.
0x0007
The system has
restarted because the
RCB was not able to
communicate with one of
the sensors.
0x0008
Temperature in the tank
is greater than the limit
set by user.
0x0009
The real time clock is out
of order.
0x000a
Real time clock has been
reset.
0x000c
The system has
restarted because the
RCB was not able to
communicate with one of
the fragrance pumps.
System behaviour
Action
Turns off the current
Check the cables and
bathing cycle and is
connections. Test with
not able to start a new
another sensor.
bathing cycle.
Turns off the current
Check the cables and
bathing cycle and is
connections. Test with
not able to start a new
another sensor.
bathing cycle.
Turns off the current
Wait until the
bathing cycle and is
temperature is equal
not able to start a new
to or below 70˚C.
bathing cycle until the
water temperature is
equal to or below
70˚C.
Turns off the current
Check the cables and
bathing cycle and is
connections. Check
not able to start a new
input voltage. Restart
bathing cycle.
system by toggling the
voltage. If the same
error is repeated,
change the RCB PCB.
Restarts the tank
Clean or change the
cycle.
electrodes. Check the
outlet.
The RCB restarts after
Restart the system.
60 seconds when it
Check the cables and
has lost the
connections. Change
connection to the
the control panel.
control panel.
The RCB restarts after
Restart system. Check
60 seconds when it
the cables and
has lost the
connections. Change
connection to the
sensor.
sensor.
Restarts the tank
Restart the system.
cycle.
Check the pipes out
from steam generator.
The time and date are
Restart the system. If
not being updated.
the same thing
happens again,
change the RCB PCB.
Time and date are set
Set time and date.
to default.
RCB and the panels
Restart the system.
restart after 60
Check the cables and
seconds.
connections. Change
fragrance pump.