5.1 Start
To start the steam generator, move your hand in front of the screen. The screen will then light up. The On/Off symbol will be
highlighted. Press OK. The On/Off icon (12) will then light up in the status display (5) to indicate that the sauna/steam generator
has been switched on. If the On/Off button (1) is not illuminated, press the Up arrow (6) to step to the right position. To switch
off, step to (1) and press OK.
While the steam generator is in operation, the current temperature and time will be displayed unless any alterations are made to
the settings.
When the steam generator is switched off, the control panel illumination will fade. It can be automatically reactivated by moving
your hand in front of the panel.
5.2 Setting the desired bathing temperature
Press the Up or Down arrow to highlight the temperature symbol (2) and press OK. Set the desired temperature using the
up/down arrows and the confirm this by pressing OK.
5.3 Setting the desired start time and programming the calendar
You can set a start time for the steam generator up to 24 hours in advance. You can also program a full week's bathing
activities, specifying start and stop times, desired temperature, which days of the week the setting applies to, and whether or not
the program is to be repeated, up to a week in advance.
To preset a start time, use the Up and Down arrows to mark the clock symbol (3) and press OK. Select Timer and Start time,
then preset the desired time by using the Up and Down arrows. Confirm each individual figure by pressing OK. A clock icon will
light up in the status display to indicate that the control panel has been programmed with a start time. A time that has already
been programmed into the control panel can be activated by stepping to Activate under the clock symbol and confirming this
previous setting with OK.
To deactivate a programmed value, step to (3), use the Down arrow to step to Activate and confirm with OK.
To create a week's bathing programme, use the Up and Down arrows to mark the clock symbol and press OK. Select Calendar
and then New activity. Then set the start time, stop time, temperature, weekdays that the program is to run and whether the
program is to be repeated each week. Also set the Activity type, in other words whether the unit is to be On or in Standby mode.
Selecting Standby ensures that the water temperature remains high, but that no steam is produced. When bathers arrive, they
simply press an external switch or an h1 panel and steam is produced immediately. When selecting the day, all days of the
week are displayed. Use the Up and Down arrows to select which day the program is to run and confirm with OK. It is possible
to select more than one day. The selected days are indicated by a tick to the right of the day. After selecting the desired
day/days, move down to the > symbol. Then select whether this program applies for the coming week only, or for every week.
When an activity (program) has been created, this is indicated by the calendar icon, which lights up in the status display.
It is possible to create multiple programs. To program more than one activity, select New Activity in the calendar menu. Up to 5
activities may be programmed.
To delete a program, select the program to be deleted in the calendar menu, then step to Remove and confirm with OK.
5.4 Locking the control panel
To prevent any unauthorised changes to programmed values, the control panel's keypad can be locked by simultaneously
pressing the Home (11) and Back (10) buttons for approximately 2 seconds. A key icon will appear in the status display. To
unlock the keypad, press the Home and Back buttons once again for approximately 2 seconds.
5.5 Settings menu
Under the settings menu are extra functions that are designed to make troubleshooting easier and that can be used to set
certain parameters. It is also possible to use this menu to reset h1 to the factory default setting. There are the following sub-
menus:
General – Used to set various parameters such as time, date, language, etc. The sub-menus under General are:
Set time – Set clock
Set date
Region – Used to set language, temperature scale (°C/°F) and time format (12 or 24-hour clock)
Sleep delay – The length of time the control panel can remain inactive before the display switches off.
Key-lock – Here you can choose to activate an automatic keypad lock (the panel locks automatically after a certain time: to
unlock, press the Home (11) and Back (10) buttons simultaneously), a code lock (which requires a correct code
to be entered before the panel can be operated) and change the code for the code lock. You also set the time
delay before the code lock is activated.
Vibration – Select whether or not you wish the panel to vibrate slightly when any buttons are pressed.
About – Displays information about the system: software/hardware versions and product ID.
Service – Under the service menu you can, for example, change the parameters that were set during the initial installation
process. The code 124 must be entered to access the service menu. The following sub-menus are available:
Settings
Bathtime limit – Maximum permissible bathing time.
Standby limit – Maximum length of time the system may be manually switched on while in standby mode.
Temperature limit – Maximum bathing temperature.
Water pressure – Current water pressure. Default is 5 bar.
Overheating limit – Maximum water temperature before the tank empties automatically.
Filtered temperature – Indicates whether you wish to see the exact thermistor value. Showing the filtered value avoids
18
fluctuations in the displayed temperature.