Translation of the original instructions
Manual mode
To start this mode:
The manual mode allows to reach the maximum power of the Gysduction. At this power, workpieces can
heat up very quickly. The closer the inductor is to the workpiece, the higher the heating power will be.
Audible heating signal
To activate/deactivate this function:
Thermal protection indicator (8)
PRODUCT START UP
1
3
INDUCTOR DESCRIPTION & USE
All operations described below require practice. GYS recommend experimenting by carrying out
tests on sheet metal or write-off.
GYSDUCTION AUTO
In this mode, the user selects the desired heating power.
Briefly press the MODE button (7) until the LED in front of « MANUAL » (5)
lights up.
Operating :
The digital display (2) shows the percentage of the maximum power (2400
W) that the inductor can transmit to the workpiece to be heated. Use the
setting buttons (1) to adjust to the desired power.
An audible BEEP can be activated to indicate heating activity. The BEEP
sounds as soon as the heating is effective and its frequency varies according
to the position of the inductor in relation to the part to be heated. The closer
the inductor, the higher the frequency.
Press the MODE button (7) for 3 seconds to activate/deactivate this BEEP.
This indicator lights up to indicate that the product has entered thermal pro-
tection due to overheating. As long as this light remains on, the product is
inoperative. It switches off when the product has cooled enough.
Heating can only be reactivated from this point on.
2
Switch on the station (1)
Accessory connection (2)
1. Select the required inductor.
2. Lift the valve on the Gysduction connector.
3. Connect the inductor connector to the Gysduction.
4. Close the valve to lock the connection.
5. The display shows the number of the connected accessory (eg.
AC1)
Connection of the control pedal (3)
The Gysduction can be supplied with a control pedal (ref. 055490),
necessary for the use of the bolt, adhesive and spiral inductors.
Connect the cable to the Gysduction and the pedal to make it
work.
Heating activation
The glass and dent pulling inductors are fitted with a heating but-
ton. The three other ones work with the control pedal.
Bring the inductor close to the metal part to be heated, then press
the inductor button or the control pedal to activate the heating.