Installation Option 2 - Front Opening - Napoleon Luxuria Serie Manuel D'installation

Masquer les pouces Voir aussi pour Luxuria Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

installation planning
EN
4.2

installation option 2 - front opening

Suitable for Dynamic Heat Control™ Plus
Suitable for Dynamic Linear Trim
Minimum air outlet opening dimensions must be followed. The opening is required to be framed no more than 1.5" below the
enclosure top (see option 2 diagram) to avoid trapping heat in the upper areas and the air outlet opening centered on the appliance
center. Framing the air outlet opening lower will overheat the appliance, the enclosure, and finishing material.
DYNAMIC HEAT
CONTROL™ AIR
OUTLET OPEN-
ING IS HOT WHEN
APPLIANCE IS
OPERATING!
Front air outlet opening must
be located out of reach of the
user. Air outlet must not be
restricted by furnishings or
decor.
Air outlet opening is required to be centered with the appliance.
LVX38
(Q x R)*
S
This dimension is determined from the enclosure height (L) minus the distance to the top of the Dynamic
Heat Control™ air outlet opening (0"-1.5"), height of the air opening (2"-3"), and the distance from the
*Free area. Any trim edging or finishing must not reduce or restrict minimum area. Grills, grates, louvres, or
other unapproved covers are not permitted and will cause a fire hazard.
28
W415-1710 / B / 08.17.18
(Q x R)*
S
L
MINIMUM AIR OUTLET OPENING DIMENSIONS
LVX50
80 sq. in. minimum (Q must be 2-3")
base of the appliance to the top of the appliance viewing area (25 11/16").
2 1/2"
min
0-1.5" Max
2-3"
6" min
Wall mounted
object (picture
frame, appli-
ance, etc.)
LVX62
160 sq. in. minimum (Q must be 2-3")
ceiling
enclosure top
must be installed
ALTERNATIVE
LVX74