Lvx38 Venting Configurations - Napoleon Luxuria Serie Manuel D'installation

Masquer les pouces Voir aussi pour Luxuria Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.5

LVX38 venting configurations

40'
38 1/2'
(462")
30'
V
20'
15'
10'
6'
(72")
5'
4 3/4'
(57")
2 1/2'
(30")
0'
Base of
air collar
1 1/2'
(18")
0'
minimum venting requirements - propane
(PROPANE ONLY)
V+H ≤ 40 ft. H ≤ 10 ft.
(For longer vent runs, a power vent is
required).
V + H are measured from the centre of vent
elbows. Elbows are considered as 90º.
Two 45º elbows = One 90º elbow.
For 0 elbow configurations, V is a minimum
of 6' to a maximum of 40'.
5'
10'
3 1/4'
(40")
Vertical termination only.
No horizontal termination allowed.
1-4 elbow zone
1-3 elbow zone
1-2 elbow zone
1 elbow zone
Refer to appliance
specific GPV/PVA
instructions for other
venting configurations.
15'
20'
H
EN
25'
23
W415-1710 / B / 08.17.18