Enclosure Design - Napoleon Luxuria Serie Manuel D'installation

Masquer les pouces Voir aussi pour Luxuria Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

12.2 enclosure design

Additional openings in the closure are not acceptable since the DHC™ system relies on the "chimney effect" cre-
ated through the appliance and the enclosure.
By adding additional air inlet(s) to an enclosure, air can bypass the appliance, which increases the operating
temperature of the appliance and around the appliance opening. This is counterproductive when trying to demon-
strate the benefits of heat management to potential customers. In extreme cases, the appliance may become hot
enough for the high limit switch to shut down the appliance.
note:
The outside of the enclosure must be finished on all four sides and must include a complete floor.
finishing
Rear wall
must also be
fully framed
and finished.
Additional air
inlet(s) or any
other type of
opening
W415-1710 / B / 08.17.18
EN