6.6
restricting vertical vents
Vertical installations may display a very active flame. If this appearance is not desirable, the exhaust outlet may be
restricted with a Wolf Steel approved restrictor kit. This kit is not recommended for short vertical vent runs.
Depending on the model and/or year of your appliance, mounting holes may not exist.
6.6.1 LVX38 / LVX50
If mounting holes exist, remove the screws from the firebox top, align the restrictor plate as illustrated and
A.
secure.
If mounting holes do not exist, align the restrictor plate as illustrated and secure using the two screws
B.
(supplied).
Ensure the plate will pivot at the slot up into the exhaust outlet.
C.
Depending on the amount of restriction desired, the restrictor plate can be left flat for most restriction or
D.
bent up for varying degrees of restriction.
Mounting
screws
6.6.2 LVX62 / LVX74
Secure 5" restrictor to mounting plate using 2 screws (supplied).
A.
Remove baffle by removing 1 screw from firebox. Set screw and baffle aside.
B.
Align mounting plate clearance holes (4) over existing screws protruding into firebox. For ease of access,
C.
ensure restrictor and mounting plate are installed with screws installed in Step A facing upwards
(into exhaust collar).
Install 4 self-drilling screws (supplied) (2 per side).
D.
note:
For ease of installation, the mounting plate was designed with 2 fixed holes and 2 slotted holes.
Reinstall baffle using screw removed in step B.
E.
FIREBOX
MOUNTING
TOP
PLATE
Firebox top
Restrictor
Exhaust collar
#8x½ hex head
sheet metal screw
1. Most restriction
2. Moderate restriction
3. Least restriction
BAFFLE
MOUNTING
SCREWS
venting installation
Top view
Restrictor
3
2
1
Firebox top
TOP VIEW
5" RESTRICTOR
TOP VIEW
EXHAUST COLLAR
5" RESTRICTOR
#8 x ½ HEX HEAD
SHEET METAL
SCREWS
1. MOST RESTRICTION
2. MODERATE RESTRICTION
3. LEAST RESTRICTION
EN
FIREBOX TOP
41