Description Daily Control; Trailer; Ventielen + Manometer; High Pressure Pump - Dibo JMB-M Mode D'emploi

Masquer les pouces Voir aussi pour JMB-M:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

DESCRIPTION DAILY CONTROL

1

Trailer

GENERAL: Check the trailer entirely for screws coming loose, cracks and/or
breakages of the welded joints and brake lines. Keep the machine as clean
as possible to avoid dirt, water, oil and spilled fuel having a unfavorable effect.
Double check the tire pressure, brakes, closing of the cap, lights ... This is
necessary for your own good and other peoples safety on the road.
2

Ventielen + manometer

At a switched off machine, this means a stopped engine, the manometer must
reflect 0 bar. At a maximum performing machine, this means operated at full
load working engine, the manometer cannot indicate more than the maximum
pressure by DiBO indicated, for your machine. After operation and releasing
the gun can still remain a small pressure remainder present. The reflected value
of the manometer must be between 0-30 bar, the valves are then all right.
3

High pressure pump

Check the pump on loose connections, bolts, seals and leaks. Check regularly
the oil level of the pump. If the oil level has decreased too much or pollution
of oil is observed, should these be replaced before working further. Put the
machine on a horizontal base. The oil level must stand halfway the level glass.
Take at doubt the oil level stick separately, where the oil level must stand
between both mark lines. If pump oil gives a milky impression, frequently
indicates this on an internal leak as a result of which water touched oil there.
Immediately repair is necessary then.
4

High pressure and low pressure parts

Check the hoses, piping and connections on external damages and leaks.
If damaged or leaks these must be immediately replaced.
5

Spray equipment

Check lances and guns on leaks, external damages and hair cracks. If damaged
or leaks these must be immediately replaced. Check the spray image of the
water jet, if these blows out to much you must replace the nozzle. Check
protective cap-nozzle on damages and replace if necessary. Check the thread
of the couplings on external damages. At damage replace without delay.
6

Electrical part

Checks visible electric wiring and components (among other things switches)
on external visible damages. If damaged let replace the concerning parts.
7

Burner

Check if the burner opening is clear of pollution. Checks pipes and connections
on leaks and external damages. Check the filter and replace if necessary.
Check the sort fuel and the pollution in the tank and clean if necessary.
Ignition transformer from the burner:
It is important that on the ignition transformer a load is connected.
The switching on of the ignition transformer without the ignition pins are
connected, are not permitted. We recommend during maintenance activities
certainly checking the connections of the ignition cables and for the case the
burner would not work, certainly don't let run the burner.
8

Water tank

Check the water tank on external damages and leaks.
Check when the tank is filling if the float system works properly.
9

Engine

Check the engine for loose parts, leaks. Check the oil level with the oil gauge.
When the oil level has gone down too much, or contamination of the oil is
found, this must be replaced before continuing the works. Check that the intake
opening is not blocked. Check the filter for extreme contamination and clean /
replace it if necessary. Check the filter for contamination and clean / replace it if
necessary.