6.3 Description daily control
6.3.1. Frame
Check the frame entirety on loosened bolts and/or cracks of the welds.
Keep the machine as much as possible clean to prevent act of dirt, water, oil and messed fuel.
6.3.2. Valves + manometer
At a switched off machine, this means a halted engine, the manometer must reflect 0 bar.
t a maximum performing machine, this means operated at full load working engine, the manometer can not
indicate more than the maximum pressure by DiBO indicated, for your machine.
After operation and releasing the gun can still remain a small pressure remainder present.
The reflected value of the manometer must be between 0-30 bar, the valves are then all right.
6.3.3. High pressure pump
Check the pump on loose connections, bolts, seals and leaks. Check regularly the oil level of the pump.
If the oil level has decreased too much or pollution of oil is observed, should these be replaced before work-
ing further. Put the machine on a horizontal base. The oil level must stand halfway the level glass.
Take at doubt the oil level stick separately, where the oil level must stand between both mark lines.
If pump oil gives a milky impression, frequently indicates this on an internal leak as a result of which water
touched oil there. Immediately repair is necessary then.
6.3.4. High pressure and low pressure parts
Check the hoses, piping and connections on external damages and leaks.
If damaged or leaks these must be immediately replaced.
6.3.5. Spray equipment
Check lances and guns on leaks, external damages and hair cracks.
If damaged or leaks these must be immediately replaced.
Check the spray image of the water jet, if these blows out to much you must replace the nozzle.
Check protective cap-nozzle on damages and replace if necessary.
Check the thread of the couplings on external damages. At damage, replace immediately without delay.
6.3.6. Electrical part
Checks visible electric wiring and components (e.g.: switches) on external visible damages.
If damaged, replace the concerning parts immediately.
6.3.7. Burner
Check if the burner opening is clear of pollution.
Checks pipes and connections on leaks and external damages. Check the filter and replace if necessary.
Check the sort fuel and the pollution in the tank and clean if necessary.
Ignition transformer from the burner:
It is important that on the ignition transformer a load is connected.
The switching on of the ignition transformer without the ignition pins are connected, are not permitted.
We recommend during maintenance activities certainly checking the connections of the ignition cables and
for the case the burner would not work, certainly don't let run the burner.
6.3.8. Water tank / fuel tank
Check the water tank / fuel tank on external damages and leaks.
Check when the water tank is filling if the float system works properly.
DiBO n.v. 64