Exhaust Noise Inspector Type 3638 – User Manual
Printout
At measurement completion, a printed report of the results is automatically activated. If an
additional printout of the most recent measurement is required, press
from the main operation menu. Press OK to confirm.
The following information is always printed in the report:
Engine speed (RPM trigger value)
Number of vehicle cylinders
Vehicle engine type: 2- or 4-stroke
Measurement date and time
Date format: yyyy-mm-dd
Time format: hh:mm:ss
Sound measurement results in dB(A): usually 3 values
Criteria level: maximum allowable noise level
L
or L
Aeq
Max
Test results: Pass/Fail
3 lines (maximum) to write additional comments
Sound level meter's serial number
Optional information that can be printed as well:
Background noise level in dB(A): if levels are too high
Compressed air noise level in dB(A)
Calibration results
value: average or maxium noise level detected
to select Printout