Installation Instructions - Single Integrated Installation
STEP 8 FINAL EXTERNAL UNIT
PREPARATION (Cont.)
Put the access cover back onto the unit and secure
with two 1/4" hex head screws.
Access
Cover

STEP 9 TOE KICK INSTALLATION

Insert Toe Kick into the slot in the Front Access
Cover by rotating it toward you.
Push the bottom portion
of the Toe Kick towards
the product and slide into
place.
STEP 10 INTERNAL UNIT
PREPARATION
Remove all tape, cardboard, and foam from the unit
(foam shipping supports may be located behind the
left and right sides of each of the glass pan fronts on
Refrigerator models).
Remove boxed door bins from shelves.
Unbox and install door bins.
Install door bin mats.
31-1000190 Rev. 2

STEP 11 START ICEMAKER

injury, avoid contact with the moving parts of the
ejector mechanism, or with the heating element that
releases the cubes. Do not place fingers or hands on
the automatic ice making mechanism while the
appliance is plugged in.
A newly-installed freezer may take 12–24 hours to
begin making ice.
1/4" Hex
The icemaker will produce seven cubes per cycle—
Screws
approximately 15 cycles in a 24-hour period,
depending on freezer compartment temperature, room
temperature, number of door openings and other use
conditions.
If the freezer is operated before the water connection
is made to the icemaker, set the power switch to
OFF. Top wire basket must be removed to access the
icemaker power switch.
When the freezer has been connected to the water
supply, set the power switch to ON.
Throw away the first full bucket of ice to allow the water
line to clear.
Be sure nothing interferes with the sweep of the feeler
arm.
When the bin fills to the level of the feeler arm, the
icemaker will stop producing ice.
It is normal for several cubes to be joined together.
If ice is not used frequently, old ice cubes will become
cloudy, taste stale and shrink.
NOTE: Icemaker works best between 40 and 120 PSI
(275-827 kPa) home water pressure.
45
(freezer models)
CAUTION
To minimize the risk of personal
(Appearance may vary)
Icemaker
Feeler Arm
Power
Switch
Icemaker
Feeler Arm
Power
Switch