Installation Instructions - Dual Integrated Installation
STEP 3 PREPARING UNIT FOR
INSTALLATION (Cont.)
WARNING
Hazard.
To avoid the risk of electric shock, make
sure the power cord is not plugged into the wall outlet.
Install the transformer into the case top assembly:
1. Remove cover top by removing eight #8 hex screws
and keep aside for assembling back the cover top.
2. Place the transformer into the case top provided in
ZKUN kit and secure it with the existing (1/4") hex
screws to left front of case top.
3. Connect the 2 pin transformer connector to the
heater connector and 3 pin connector to panel
control, make sure locking tabs are engaged.
4. Verify the master switch is on.
5. Assemble the cover top with screws save from
previous step.
6. Enclosure assembly upper is hidden for clarity.
#8 Hex
Screws
2 Pin
Connector
to Heater
Connector
Transformer
3 Pin
Connector
Master Switch
STEP 4 INSTALL ANTI-TIP BRACKET
WARNING
These appliances are top heavy, especially with any
doors open, and must be secured to prevent tipping
forward which could result in death or serious injury.
Read and follow the entire installation instructions
for securing the appliance with the anti-tip system.
Remove the anti-tip bracket from the hardware kit.
Anti-tip bracket should be mounted against the back
wall or up to 25-1/2" (64.7 cm) maximum from front of
opening. Use floor mounting method if the bracket is
not against a wall (bracket hardware is provided for
mounting into wood, steel studs and concrete).
31-1000190 Rev. 2
Electrical Shock
Cover Top
Tip Over Hazard.
STEP 4 INSTALL ANTI-TIP BRACKET
(Cont.)
LH Unit
18"
24"
26-5/8"
23-1/2'
67.6 CM
59.6 CM
32-5/8"
29-1/2"
67.6 CM
59.7 CM
38-5/8"
35-1/2"
67.6 CM
59.7 CM
Measure and mark from the RH side of the opening
per the table above depending on the size of the RH
unit you are installing.
Measure and mark again from the RH side of
the opening per the table and depending on your
combination of LH and RH units.
For example, if installing an 18" LH unit and a 30" RH
unit, use 5-3/4" and 38-5/8".
Mount the anti-tip bracket centered about the marks
and flush to the floor as shown. Mark 3 holes for wall
mounting or 4 holes for floor mounting.
WOOD MOUNTING: Predrill with 3/16" drill bit, 2"
deep, then install lag bolts with a 7/16" driver.
CONCRETE MOUNTING: Predrill with a 5/32"
concrete bit, 2" deep, then install
tapcon screws with a 7/16" driver.
STEEL MOUNTING: Predrill with a
1/2" drill bit, insert toggle, then install
bolts with a 7/16" driver.
The bracket must be screwed to
either the FLOOR or REAR WALL.
If the enclosure is deeper than 25 ½", the anti-tip
bracket should be secured to the floor 25" from front
of the enclosure.
Tape the waterline to the wall and floor approximately
3" to the left of the anti-tip bracket. Apply tape about
every 5" toward the front of the opening (tape will
prevent the unit from rolling over the waterline during
installation). Do not tape near the cabinet front in
order to keep tape hidden under the unit.
3"
17
RH
30"
23-1/2"
8-7/8"
59.7 CM
22.5 CM
29-1/2"
5-3/4"
59.7 CM
22.5 CM
35-1/2"
5-3/4"
59.7 CM
22.5 CM
RH Unit
LH Unit
3"
5"
5"
UNIT
18"
24
30