Installation Instructions - Single Integrated Installation
STEP 7 LEVEL UNIT
All models have 4-point leveling. The front is supported
by leveling legs; the rear is supported by adjustable
wheels. Both are accessible from the front of the unit.
To level the back of the unit, turn the 7/16" hex
nut located above the front wheels. Turn clockwise
to raise or
counterclockwise
to lower the unit.
For front leveling,
use a 7/16" open-
Hex nut adjusts
end wrench.
rear wheels
Adjust height
of unit to match
installation cutout
opening 84". The
unit should be
level and plumb
with cabinetry.
NOTICE: The rear leveling wheels and front leveling
legs are limited to a maximum height adjustment of 1".
If the installation requires more than 84" height, the
installer should elevate the unit on a sheet of plywood
or runners. Cabinetry trim could also be added across
the top of the opening to shorten the opening. If you
attempt to raise the unit more than 1", you will damage
the front leveling legs and the rear leveling wheels.
STEP 8 FINAL EXTERNAL UNIT
PREPARATION
FOR FLUSH INSTALLATION:
of the door is 7/8" behind front face of surrounding
cabinets BEFORE securing brackets to the surrounding
cabinetry.
Open the doors to
the units. Locate
removal tool.
Filter should be as
shown.
counterclockwise (use
needed).
remove. NOTE: Water
Open-end wrench
adjusts front
leveling legs
Make sure front surface
Compartment Door
Filter
Mounting
Hook
Filter Removal Tool
STEP 8 FINAL EXTERNAL UNIT
PREPARATION (Cont.)
Make sure lights are on inside the unit. If they are not
on, check to make sure the master switch is on by
removing the front enclosure which is secured with
six 1/4" Hex screws.
Switch on the master switch if not on. (Master Switch
Wires hidden for clarity.
Assemble the enclosure with removed screws.
Predrill 1/16" holes is both the sides of the surround
1/2" deep through holes in the enclosure.
Secure unit by driving four 1/4" hex screws to both
sides to surrounding cabinetry. NOTE: This step does
NOT replace the anti-tip safety hardware. Refer to
Step 4 Installing Anti-Tip Bracket and Step 7 Inserting/
Securing into Cabinet Surround for details on installing
the anti-tip hardware. Repeat for the second unit.
as shown.
tool if needed).
mounting hook.
Close the compartment door.
44
1/4" Hex Screws
Master Switch
1/4" Hex Screws
31-1000190 Rev. 2