Installation Instructions - Single Integrated Installation
STEP 3 PREPARING UNIT FOR
INSTALLATION
Place the unit in front of the installation opening in a
way that the unit is in front of the intended installed
location.

STEP 4 INSTALL ANTI-TIP BRACKET

WARNING
This appliance is top heavy, especially with any
doors open, and must be secured to prevent tipping
forward which could result in death or serious injury.
Read and follow the entire installation instructions
for securing the appliance with the anti-tip system.
Remove the anti-tip bracket from the hardware kit.
Anti-tip bracket should be mounted against the back
wall or up to 25-1/2" (64.7 cm) maximum from front of
opening. Use floor mounting method if the bracket is
not against a wall (bracket hardware is provided for
mounting into wood, steel studs and concrete).
Unit
From Enclosure
18"
8-7/8"
(22.5 cm)
24"
5-3/4"
(14.6 cm)
30"
5-3/4"
(14.6 cm)
Measure and mark from the right side of the opening
per the table depending on the size of the unit you
are installing.
Mount the anti-tip bracket centered about the mark
and flush to the floor as shown. Mark 3 holes for wall
mounting or 4 holes for floor mounting.
WOOD MOUNTING: Predrill with 3/16" drill bit, 2"
deep, then install lag bolts with a 7/16" driver.
CONCRETE MOUNTING: Predrill with a 5/32"
concrete bit, 2" deep, then install tapcon screws with
a 7/16" driver.
STEEL MOUNTING: Predrill with a
1/2" drill bit, insert toggle, then install
bolts with a 7/16" driver.
The bracket must be screwed to
either the FLOOR or REAR WALL.
If the enclosure is deeper than 25
½", the anti-tip bracket should be
secured to the floor 25" from front of the enclosure.
Tip Over Hazard.
STEP 4 INSTALL ANTI-TIP BRACKET
(Cont.)
Tape the waterline to the wall and floor approximately
3" to the left of the anti-tip bracket. Apply tape about
every 5" toward the front of the opening (tape will
prevent the unit from rolling over the waterline during
installation). Do not tape near the cabinet front in
order to keep tape hidden under the unit.
STEP 5 CONNECT WATER SUPPLY
WARNING
Connect to potable water supply
only. A cold water supply is required for automatic
icemaker operation. The water pressure must be
between 40 and 120 psi (275-827 kilopascals).
WARNING
Attach tubing clamp using existing hole only. DO
NOT drill into the refrigerator.
House
Water Supply
Locate and bring the tubing to the front of the
cabinet.
Turn the water on to flush debris from the line. Run
about a quart of water through the tubing into a
bucket, then shut off the water.
Remove strain relief screw to allow for enough slack
to make a proper water connection. (Screw must be
replaced in the next step.)
Strain Relief
Screw
42
3"
5"
ELECTRIC SHOCK HAZARD
Refrigerator/
Freezer
Freezer
Water Supply
Water Supply