Step 8 Level Unit; Step 9 Final External Unit Preparation - Monogram ZIR241NPNII Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Instructions - Dual Retro-Fit Installation

STEP 8 LEVEL UNIT

All models have 4-point leveling. The front is supported
by leveling legs; the rear is supported by adjustable
wheels. Both are accessible from the front of the unit.
To level the back of the unit, turn the 7/16" hex nut
located above the front wheels. Turn clockwise to
raise or counterclockwise to lower the unit.
For front leveling, use a 7/16" open-end wrench.
Adjust height of unit to match installation cutout
opening 84". The unit should be level and plumb with
cabinetry.
Hex nut adjusts
rear wheels
Open-end wrench
adjusts front
leveling legs
NOTICE: The rear leveling wheels and front leveling
legs are limited to a maximum height adjustment of 1".
If the installation requires more than 84" height, the
installer should elevate the unit on a sheet of plywood
or runners. Cabinetry trim could also be added across
the top of the opening to shorten the opening. If you
attempt to raise the unit more than 1", you will damage
the front leveling legs and the rear leveling wheels.
STEP 9 FINAL EXTERNAL UNIT
PREPARATION
Open the doors to
the units. Locate
removal tool. Filter
should be as shown.
counterclockwise
tool if needed).
remove. NOTE: Water
system will not function
Compartment Door
Filter
Mounting
Hook
Filter Removal Tool
STEP 9 FINAL EXTERNAL UNIT
PREPARATION (Cont.)
Make sure lights are on inside the unit. If they are not
on, check to make sure the master switch is on by
removing the front enclosure which is secured with
six 1/4" Hex screws.
Switch on the master switch if not on. (Master Switch
Wires hidden for clarity.
Assemble the enclosure with removed screws.
Predrill 1/16" holes is both the sides of the surround
1/2" deep through holes in the enclosure.
Secure unit by driving four 1/4" hex screws to both
sides to surrounding cabinetry. NOTE: This step
does NOT replace the anti-tip safety hardware. Refer
to Step 4 Installing Anti-Tip Bracket and Step 7
Inserting/Securing into Cabinet Surround for details
on installing the anti-tip hardware. Repeat for the
second unit.
Locate blue arrow on
align arrow as shown.
removal tool if needed).
mounting hook.
Close the compartment door.
34
1/4" Hex Screws
Master Switch
1/4" Hex Screws
31-1000190 Rev. 2