Malfunctions
12.
malfuncTiOns
malfunction
remedial action
Actuator does
Control connection interchanged*
not switch.
SFA: Connecting control connection 1
SFB: Connecting control connection 1
SFI
Control connection 1: Open
Control connection 2: Close
* See diagram "Pneumatic Connection" in the
chapter of the same name.
Control pressure too low
See pressure specifications on the rating plate.
Medium pressure too high
See pressure specifications on the rating plate.
Flow direction reversed
See direction arrow on the housing.
Type 2300
malfunction
remedial action
Valve is not
Dirt between seal and valve seat
→
sealed.
Installing dirt trap
Seat seal worn
→
Installing a new control cone
Flow direction reversed
See direction arrow on the housing.
Medium pressure too high
See pressure specifications on the rating plate.
Control pressure too low
See pressure specifications on the rating plate.
Valve is leaking
Stuffing box worn
→
on the release
Replacing actuator.
bore.
english
31