Malfunctions; Spare Parts - Burkert 2030 Manuel D'utilisation

Vannes à membrane, commandé par piston
Masquer les pouces Voir aussi pour 2030:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Types 2030, 2031, 2031 K, 2032,

Malfunctions

12.
MalfuncTiOns
Malfunction
Actuator does
Control connection interchanged *
not switch
CFA
CFB
CFI
* see Fig. 29:Pneumatic Connection in the chapter of
the same name.
Control pressure too low
See pressure specifications on the rating
plate.
Medium pressure too high
See pressure specifications on the rating
plate.
Valve is not
Medium pressure too high
sealed
See pressure specifications on the rating
plate.
Control pressure too low
See pressure specifications on the rating
plate.
Flow rate
PTFE diaphragm bulging
reduced
Replace diaphragm.
2033, 2037
Cause / remedial action
Connect lower control connection
Connect upper control connection
Upper control connection: Close
Lower control connection: Open
13.
spare parTs
Warning!
risk of injury when opening the actuator housing!
The actuator contains a tensioned spring. If the housing is opened,
there is a risk of injury from the spring jumping out!
Carefully open the actuator housing and hold it in such a way
that any parts which jump out cannot injure anyone or damage
anything.
CauTion!
risk of injury and/or damage by the use of incorrect parts!
Incorrect accessories and unsuitable spare parts may cause injuries
and damage the device and the surrounding area.
Use only original accessories and original spare parts from
Bürkert.
Types 2030, 2031, 2031 K, 2032 and 2033 are available as spare
parts for the piston-controlled diaphragm valves.
Seal set,
Diaphragm.
English
35

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

20312031 k203220332037

Table des Matières