11
malfuncTiOns
malfunction
remedial action
Actuator does
Pilot air port interchanged
not switch.
CFA:
Connecting pilot air port 1
CFB:
Connecting pilot air port 1
CFI
Pilot air port 1: Open
Pilot air port 2: Close
Pilot pressure too low
See pressure specifications on the type label.
Medium pressure too high
See pressure specifications on the type label.
Flow direction reversed
See direction arrow on the body.
Tab. 21: Malfunctions - 1
See "Fig. 23: Pneumatic connection" .
14)
40
14)
english
Type 2300
Malfunctions
malfunction
remedial action
Valve is not
Dirt between seal and valve seat
→
sealed.
Installing dirt trap
Seat seal worn
→
Installing a new control cone
Flow direction reversed
See direction arrow on the body.
Medium pressure too high
See pressure specifications on the type label.
Pilot pressure too low
See pressure specifications on the type label.
Valve is leaking
Packing gland worn
→
on the release
Replacing packing gland.
bore.
Tab. 22: Malfunctions - 2