8.4.1.
connection of the control medium
Control functions a and B:
→
1 of the activation unit
On connection
(see diagram: "Pneumatic Connection")
Control function i:
→
On the connections
1 and 3 of the activation unit
(see diagram: "Pneumatic Connection")
→
Pressure on connection 1 opens the valve.
→
Pressure on connection 2 closes the valve.
Air discharge connection SFA, SFB and
second control air connection SFI
Control air connection SFA, SFB, SFI
Fig. 12:
Pneumatic Connection
Control air hose:
6/4 mm or 1/4" control air hoses can be used.
A control air connection via G 1/8 thread is available as an option.
Type 2300
Installation
3
1
8.4.2.
rotation of the actuator module
The position of the connections can be aligned steplessly by rotating
the actuator module through 360°.
Only the entire actuator module can be rotated. The activation
unit cannot be rotated contrary to the actuator.
When aligning the connections, ensure that the valve is in
the open position.
procedure:
→
Clamp the valve housing in a holding device
(applies only to valves which have not yet been installed).
→
Counter on the flats of the nipple with a suitable open-end
wrench.
→
Fit special wrench* exactly into the wrench contour on the
underside of the actuator module.
Warning!
risk of injury from discharge of medium and pressure!
If the direction of rotation is incorrect, the interface between the
valve housing and nipple may become detached.
•
To align the connections,
rotate the actuator anti-clockwise only.
english
25