Jam message
Inactivity Stoppage
Incompatible iBOTs
Detected
Input Section E-
Stop Pressed
Load Failure Jam
Mechanical Over-
height Sensor
Blocked
No iBOTs Detected
Statistics
Description
The machine can be configured to stop automatically
after a period of inactivity. An Inactivity Stoppage is
initiated by the External Link Component (ELC). If
stopping after a period of inactivity is not desired, or a
different period of inactivity before the stop is desired,
the option can be changed or disabled in the ELC
settings under the Sorter heading using the option for
Inactivity Timeout.
The Real-Time Controller has detected an iBOT in the
system that is incompatible with the Controller. This
can happen if the Controller software is upgraded, but
the iBOTs are not, when an iBOT upgrade is
necessary. If the software version is below the
Controller set minimum, this error will occur, and the
iBOT will need to be removed to be upgraded
manually.
Occurs if the Emergency Stop (E-Stop) switch in the
input section (indicated in the picture) has been
pressed. E-Stop switches enable a quick stop of all
motors in the machine in the event of an emergency
involving potential personnel injury.
Occurs when a piece is not loaded properly onto an
iBOT at the loading position.
The Mechanical Over-height sensor is located on the
input section of the machine, and detects whether a
piece going down the conveyor exceeds the
maximum height limit of the system. If the mechanical
lock is broken upon startup of the system, a jam will
be triggered.
Occurs when the Real-Time Controller cannot detect
any iBOTs in the system.
Sure Sort™ Operator Manual
OPEX Corporation
153