2.6.7. Restoring the machine to normal operation
After the jam is cleared or the required maintenance or repair is complete, the
Authorized Employee shall restore the machine to normal operation as follows:
1. Remove all tools and other materials from the area.
2. Ensure the machine is closed up and operationally intact.
3. Notify operators and affected persons that the machine will be restarting.
4. Make sure everyone is safely away from the machine.
5. Verify all controls are set to the neutral or OFF position.
6. Remove all LOTO devices and "Caution" sign.
7. Restore equipment to service, and verify that the machine is safe to
operate.
8. Notify operators and affected persons that LOTO devices have been
removed and equipment is now ready for use.